Becton Dickinson (BD) is recalling all ethylene oxide (EtO) sterilised BD Venflon Pro Safety (VPS) and Venflon Pro IV Cannulae after identifying an increase in reports of leakage from the injection port.
-
BD have notified the MHRA that the sterility of some of their devices cannot be guaranteed due to quality issues with their third-party sterilisation provider.
-
Eaststone Limited has informed us of an issue related to underfilled or empty bottles for MidaBuc - Midazolam (as HCL) 10mg/mL Oromucosal Solution. The below batch is being recalled.
-
Gilead Sciences Ltd has informed us of a quality defect issue, in relation to specific lots of 5µm sterile filters, which are co-packed in cartons of the AmBisome product. The medical device is called Minisart Filter 16534-…
-
Guerbet Laboratories Limited is recalling certain batches of products as a precautionary measure due to reports received from healthcare professionals on the difficulties in attaching the Luer lock adapter to the Luer tip of…
-
Manufactured by Philips – the rotary therapy selector switch may fail resulting in unexpected device behaviours which could lead to a delay or failure in delivering therapy.
-
The Philips HeartStart MRx Monitor/Defibrillator MRx may fail to identify a fault and alert the user in the event of internal damage suffered during a drop or due to severe mechanical shock.
-
Pharmaswiss Česka republika s.r.o. (an affiliate of Bausch & Lomb UK Limited) is recalling all unexpired batches of Emerade 500 microgram auto-injectors (also referred to as pens) from patients due to an error in one com…
-
Pharmaswiss Česka republika s.r.o. (an affiliate of Bausch & Lomb UK Limited) is recalling all unexpired batches of Emerade 300 microgram auto-injectors (also referred to as pens) from patients due to an error in one com…
-
Manufactured by NuVasive Specialized Orthopedics – supply of all MAGEC rods suspended to the UK market during a review by MHRA.
-
Manufactured by NuVasive Inc. – risk of end cap separation after implantation.
-
Pharmaswiss Česka republika s.r.o. (an affiliate of Bausch & Lomb UK Limited) is recalling all unexpired batches of Emerade 150 microgram auto-injectors (also referred to as pens) from patients due to an error in one com…
-
Manufactured by Cardinal Health – calibration period revised to 25 weeks instead of yearly to ensure these thermometers remain within their accuracy range and reduce the risk of misdiagnosis or delay in treatment.
-
Manufactured by Terumo BCT – inadequately broken anticoagulant ‘frangible’ may lead to clotting and inadequate therapy during apheresis procedures.
-
This recall affects Mitomycin-C Kyowa 2 mg (PL 16508/0042), 10 mg (PL 16508/0043), 20 mg (PL 16508/0044), powder for solution for injection, and Mitomycin-C Kyowa 40 mg (PL 16508/0045), powder for intravesical solution.
-
Manufactured by Philips – due to a software or hardware issue the device may fail to start or deliver defibrillation therapy.
-
Manufactured by Baxter – Communication error alarms may result in unintentional delay and interruption of treatment due to system shutdown.
-
GlaxoSmithKline, trading as Glaxo Welcome Ltd, is recalling all unexpired stock of Zantac (ranitidine hydrochloride) prescription only medicines (POM) from pharmacies.
-
Manufactured by Defiteq International BV or GGT Holding BV – the safety and performance of these devices cannot be verified and their safe use can no longer be assured.
-
Manufactured by Becton Dickinson (BD) – tubes may contain a hole or be damaged or deformed, potentially causing blood leakage and/or an inadequate blood-to-additive ratio leading to incorrect test results.
-
Manufactured by Philips – this problem affects lithium ion batteries that have exceeded their specified replacement interval or number of charging cycles.
-
[Archived] Manufactured by Vyaire – Cartridges with an aluminium warming plate in the fluid pathway can lead to an IV infusion containing aluminium above currently recommended safe levels.
-
Manufactured by Roche Diabetes Care – Important instructions on how to fit 2 separate key frames to prevent accidentally activating the pump (MDA/2019/009).
-
Aguettant Limited has informed the MHRA that there is an error in the Patient Information Leaflet (PIL) for batches of Atropine Sulfate 3mg/10ml Solution for injection in pre-filled syringe.
-
Actavis Group PTC EHF is recalling the below batches from pharmacies as a precautionary measure due to possible contamination with N‑nitrosodiethylamine (NDEA).
-
Manufactured by Eurotrol B.V – may give readings below the values assigned to the product, leading to incorrect measurement results.
-
Manufactured by Abbott – some users who are experiencing an immune response to the adhesive are applying creams, patches or sprays under their sensor to reduce skin reactions, which may affect device performance.
-
Macleods Pharma UK Limited is recalling the below batches from pharmacies as a precautionary measure due to possible contamination with N‑nitrosodiethylamine (NDEA).
-
Manufactured by GE Healthcare – Device may stop ventilation when in PSV Pro Mode and users may be unable to change gas and agent settings when using End-Tidal Control.
-
Actavis Group PTC EHF is recalling the below batches from pharmacies as a precautionary measure due to possible contamination with N‑nitrosodiethylamine (NDEA).
-
List of field safety notices (FSNs) from medical device manufacturers from 17 - 21 December 2018
-
Manufactured by Acutronic Medical Systems AG – Ventilator may switch off without user input, deliver incorrect ventilation or may fail to alarm.
-
List of field safety notices (FSNs) from medical device manufacturers from 10 - 14 December 2018
-
Some valsartan containing products including certain batches supplied by Teva UK Limited and all unexpired batches supplied by Mylan are being recalled.
-
Philips M3538A lithium-ion batteries manufactured from 28 December 2017 to 20 March 2018 inclusive for the HeartStart MRx monitor/defibrillator may have an internal component failure.
-
Cadiasun Pharma GmBH has informed us that there is an error on the patient information leaflet for Caspofungin 70mg powder for concentrate for solution for infusion.
-
IPS Specials are recalling specific batches of Melatonin 10 mg capsules because they have been assigned an incorrect extended expiry date.
-
Kyowa Kirin is advising caution in use for one lot of Bleo-Kyowa®, Powder for Solution for Injection, 15,000 IU following the detection of glass particles (EL (18) A/09)
-
FDC Pharma are recalling batch 087B087 due to an out of specification result for an unknown impurity during stability testing. (EL(18)A/08)
-
Caution in Use: Distribute to Pharmacy and Clinic Level.
-
Summary List of field safety notices (FSNs) from medical device manufacturers from 26 February – 02 March 2018
-
Manufactured by AFP Medical – do not use affected nebulisers as they have been manufactured to unknown standards and their safety cannot be verified (MDA/2018/008).
-
Caution in Use - Distribute to Hospital Pharmacy, Ward, Chemotherapy Unit and Clinic Level. (EL (18) A/05)
-
Glaxo Wellcome UK Limited is recalling one lot of Seretide Accuhaler 50/250mcg because a manufacturing issue has resulted in a small number of units not delivering the full number of doses. (EL (18) A/04)
-
Glaxo Wellcome UK is recalling two Lots of Ventolin Accuhaler 200mcg because a manufacturing issue with these Lots has been identified which has resulted in a small number of units not delivering the full number of doses (EL…
-
Manufactured by ICU Medical (formerly Hospira) – potential for connectivity engine module to disengage from main chassis, which may lead to power down without an alarm (MDA/2018/006).
-
The supply of batteries for these devices has been temporarily stopped so there may be a significant delay in the fulfillment of orders for new batteries.
-
Caution in Use: Distribute to Hospital Pharmacy and Ward Level.
-
Caution in Use: Distribute to Pharmacy, Hospital, GP, Dental Practice, Ward and Clinic Level.
-
Summary List of field safety notices (FSNs) from medical device manufacturers from 27 November to 1 December 2017.