Biennial report on reservoir safety: 1 January 2023 to 31 December 2024
Updated 26 June 2025
Applies to England
1. Executive summary
This report is a review of reservoir compliance and enforcement of large raised reservoirs (LRRs) in England. It covers the period from 1 January 2023 to 31 December 2024. Over this period the number of registered reservoirs increased from 2,117 to 2,142.
It includes work done by the Environment Agency’s Reservoir Regulation Team to:
- protect the public
- ensure compliance with the Reservoir Act 1975
It also includes data on reservoir registration.
The reservoir safety industry learnt many lessons from the incident at Toddbrook Reservoir in 2019. The Independent Reservoir Safety Review Report was published in 2020. In response, we established a reservoir safety reform programme. We are working on this in partnership with the Department for Environment, Food and Rural Affairs (Defra), Welsh Government and Natural Resources Wales (NRW).
The Environment Agency’s ambition is to become a more digitally enabled, confident regulator. We are already adopting this approach in reservoir regulation and have more actions planned for the coming years. Our focus in 2023 and 2024 has been:
- finding new solutions to long-standing problems
- pro-actively enabling compliance for reservoir owners
- working in partnership and being transparent with our processes
- doing more with the resources we have
- making it easier for organisations to work with us
This is in line with the Environment Agency’s organisational strategy.
There have been no significant incidents resulting in loss of life and no total failures of a dam or reservoir in 2023 and 2024.
Climate change has led to increasing weather extremes. Many reservoirs in England are also aging. This means that our role, regulating reservoir safety, is becoming more and more important. We protect communities from the danger of flooding, which is one of the Secretary of State’s strategic priorities for Defra.
2. Background
Reservoirs in England have a good safety record. The last reservoir failure that led to loss of life in England was more than 100 years ago. Twenty-one people died after the failure of two dams in North Wales in 1925. This tragedy led to the passing of the Reservoir (Safety Provisions) Act 1930.
Parliament updated and superseded this act with the Reservoirs Act 1975 (the Act). Parliament amended this later act by means of the Flood and Water Management Act 2010.
Originally, local authorities were responsible for enforcing the Act. The Water Act 2003 transferred this responsibility to the Environment Agency. On 1 April 2013, NRW became the enforcement authority for LRRs in Wales. We (the Environment Agency) remain responsible for LRRs in England.
Although the safety record in England is good, we cannot be complacent. The risk from reservoirs can be significant if unmanaged. Reservoir operators and owners (undertakers) are responsible for making sure their reservoirs are safe.
Our role, as the regulator, is to make sure that undertakers follow the legal safety requirements of the Act. We follow the Regulators Code, which means we regulate in a consistent, fair and risk-based way.
3. Our role
We track compliance at all LRRs in England. NRW does this in Wales. The Scottish Environmental Protection Agency (SEPA) regulates according to the Reservoirs (Scotland) Act 2011.
As the regulator, we must:
- maintain a register of all reservoirs
- make sure that undertakers follow the Act by monitoring compliance and engaging with them
- make sure that undertakers appoint a construction engineer. Their role is to supervise the construction, alteration, discontinuance or abandonment of LRRs
- make sure that undertakers have emergency on-site flood plans for their reservoirs. These must set out the actions they would take to control flooding in the unlikely event of a reservoir emergency
- designate reservoirs as ‘high-risk’ if an uncontrolled release of water from the reservoir could endanger human life
- make sure that undertakers appoint a supervising engineer for their high-risk reservoirs
- make sure that undertakers have their high-risk reservoirs inspected by inspecting engineers
- make sure undertakers carry out any safety measures recommended by inspecting engineers
- appoint engineers and commission safety work when an undertaker does not comply with the Act - we charge undertakers for this
- appoint engineers and take any other action necessary in an emergency - we charge undertakers for this
- make sure that undertakers report reservoir incidents and share lessons learnt from them
- make sure that we observe and follow the requirements of the Act for our own reservoirs
Our role extends beyond monitoring the compliance of LRRs.
We also:
- take enforcement action on undertakers who fail to comply with the Act, when it is appropriate to do so
- work with undertakers to provide advice and guidance so they can operate their reservoirs safely
- engage with the British Dam Society (BDS) and Institution of Civil Engineers (ICE) to improve knowledge and capability in the industry
- advise Defra on operational implications of policy
- lead and inform research and development projects to improve knowledge on reservoir safety
- work with international partners to share knowledge and lessons learned to improve our own practises
- commission and maintain reservoir flood maps for all operational reservoirs - we use these for emergency planning and risk assessment purposes
- contribute to legislative reviews and improvements
The Environment Agency operates 222 of the 2142 reservoirs in England for flood risk and water management purposes. This is done by our operational area-based teams and overseen by 27 different supervising engineers. Sixteen of these 222 reservoirs are under the supervision of an independent construction engineer. These reservoirs are either being built or altered.
The Reservoir Regulation team is within the Flood and Coastal Risk Management Directorate. We work in different directorates to ensure our operational and regulatory roles are separate.
4. Our activities
4.1 Compliance and Enforcement
We assign a risk designation of high-risk or not high-risk to each LRR in England. We base it on risk to life in the event of an uncontrolled release of water from the reservoir. We have improved our risk designation process by introducing monthly case reviews. This has allowed us to clear the backlog of designations. We sent 49 final risk designation confirmation letters in 2023 and 2024. We have ensured that we have a resilient and robust risk designation panel to provide greater assurance of the process.
To enhance reservoir safety and compliance, we implemented compliance action plans in 2024. Compliance action plans are agreements with undertakers focussing on addressing specific safety concerns at their sites. They outline:
- important milestones
- risk mitigation measures
- timelines
This makes sure that reservoirs are safe during periods of non-compliance. By using this approach, we support undertakers to progress towards compliance. We worked with undertakers to create 6 compliance action plans in 2024.
We held regular reservoir safety account management meetings with major undertakers. These include:
- water companies
- Canal and Rivers Trust
- the National Trust
- Forestry England
- Environment Agency
We discussed:
- operational challenges
- outstanding compliance issues
- best practice
This ensured that reservoirs were maintained to the highest standards of safety.
We created a risk mitigation matrix to support our risk-based approach and guide our enforcement decisions. We prioritised cases by assessing risks to public safety.
We collaborated with devolved authorities in 2023 and 2024. This has strengthened our enforcement framework and facilitated the sharing of best practices. Our enforcement framework is the structured approach we use to address non-compliance. It outlines the steps we take for monitoring, identifying and managing non-compliant reservoirs.
NRW have also adopted compliance action plans. We have worked on enforcement with the Scottish Environmental Protection Agency. We have worked with the Department for Infrastructure in the Northern Ireland Executive, sharing learning and supporting their introduction of reservoir safety practices.
4.2 Reservoir safety reform
We have developed the reservoir safety reform programme. This is in response to the recommendations in the Independent Reservoir Safety Review Report. We have an excellent reservoir safety record in England. However, there are reasons to re-evaluate how we regulate reservoir safety. These include the Toddbrook incident in 2019, increasing demands on water supply, and climate change impacts. We have made changes in response to the recommendations in the report.
In 2023, we created a dedicated page on gov.uk for reservoir safety guidance documents. We have already developed and published new guidance to support engineers and owners.
Inspecting engineers guidance will ensure that engineers’ reports are:
- systematic
- detailed
- impartial
Guidance on how to manage your LRR offers simple advice to owners.
Wales joined the reservoir safety reform programme in 2024. The Welsh Government and NRW are working closely with Defra and the Environment Agency.
We are considering the options for modernising the reservoir safety legal framework. The preferred approach is bringing regulation into the environmental permitting regime.
We have looked at different options for the new hazard classification. The preferred approach is a hazard classification with four classes which uses a risk-based approach. We are also working to improve the reservoir safety management system. We are engaging with the industry to gather views to inform and shape the developments.
In 2023 we ran a voluntary information gathering exercise. This allowed owners of small raised reservoirs to provide us with some basic information about their reservoirs. These are reservoirs with a capacity between 10,000 cubic metres and 25,000 cubic metres. This has helped inform the small raised reservoirs element of the reservoir safety reform programme.
We have worked with industry when making our changes. We have used surveys, set up advisory groups and presented and ran several workshops at the British Dam Society Conference in 2024. Feedback from these activities will shape the changes we are proposing.
We are planning a formal public consultation on the reform proposals later in 2025.
Single reservoir owners
In September 2024, we conducted a telephone survey, reaching out to all 519 single reservoir owners listed on our database. The aim was to learn more about owners’ and operators’ understanding of reports and their roles and responsibilities. The survey had a high participation rate and provided us with valuable information.
As a result:
- fifty-seven single reservoir owners have now signed up to volunteer for our focus and engagement groups
- we held our first webinar with the volunteers in November 2024
- we have developed a programme to continue regular engagement to support the reservoir safety reforms
Review of engineers’ reports and statements
The Independent Reservoir Safety Review recommended that we should be able to give feedback on the quality and consistency of reports from engineers. We have strengthened our role and developed an ongoing national assessment of the quality of the reports.
The reports include:
- supervising engineers’ annual statements
- inspecting engineers’ reports
In 2023 and 2024, we reviewed 240 reports and provided guidance and training to engineers. Every supervising engineer and all reservoirs panel engineer has now received a report review.
This action has led to a significant improvement in the quality of reports over this time.
We produced new guidance for reservoir inspecting engineers on these reports and statements. This has received support and agreement from all reservoirs panel engineers who carry out these inspections. This guidance aims to improve the clarity and consistency of reports. This makes it easier for reservoir owners to understand the requirements.
4.3 Research and development
In 2024 we completed a project providing new guidance on removing or repurposing redundant reservoirs. This was delivered through the Defra and Environment Agency Joint Research Programme. This project sets out the steps to consider when removing or repurposing a reservoir. It covers:
- legislation
- planning implications
- construction
- long-term management of the asset
As well as the report, there is a downloadable tool to help compare options. Environment Agency Joint Research Programme. This project sets out the steps to consider when removing or repurposing a reservoir. It covers legislation, planning implications, construction, and the long-term management of the asset. As well as the report, there is a downloadable tool to help compare options.
We continue to collaborate with our international partners. We use the experiences from others to enhance our own practices. We can share our successes and lessons learned to keep improving dam safety globally. We have facilitated online knowledge exchange sessions on regulation change and attended meetings to discuss regulation of small raised reservoirs and climate change risks. We shared lessons learned from incidents with the European Dam Safety Authorities Network.
4.4 Digital innovation
Section 12 automation project
In 2024 we worked with the Accelerated Capability Environment, part of the Home Office innovation unit. The project was a proof of concept to find out if artificial intelligence (AI) can tell us if a reservoir is compliant. The intent was to improve our process for reviewing and uploading compliance information. This information comes from Section 12 written statements. We will continue to develop the concept in 2025.
The aim is to:
- improve efficiency by decreasing the working hours spent reviewing and uploading compliance information
- improve turnaround times for customers, increasing their satisfaction
- improve the overall quality of the data uploaded into our documentation system
- quickly identify incomplete reports, ensuring that we only process complete and accurate reports
- prepare for the potential increase in statements received
5. A risk-based approach to enforcement
The main causes of non-compliance are where an undertaker has not:
- appointed a supervising engineer to oversee ongoing safety
- appointed an inspecting engineer to carry out the statutory inspection
- completed safety measures identified by the inspecting engineer by the date specified in the inspection report
We continue to focus on reservoirs which pose the greatest risk to public safety. Our main priority is to make sure reservoirs have the correct supervision and that safety works are carried out when required. We make sure that reservoirs always have a construction or supervising engineer appointed. Not having an engineer appointed at the right time poses a significant risk to the safety of that reservoir and communities downstream.
A construction engineer supervises a reservoir when it is being built or altered. They will issue a final certificate when the work is completed. The undertaker must then appoint a supervising engineer.
A supervising engineer supervises a high-risk reservoir once it has been built and is in operation. This is a continuous appointment. They visit the reservoir and write an annual statement for the undertaker.
This statement includes the actions:
- the engineer has taken to monitor the reservoir
- the undertaker has taken to maintain the reservoir
The supervising engineer is the most important contact if an issue arises at a reservoir.
The undertaker must employ an inspecting engineer to carry out a statutory inspection of a high-risk reservoir at least once every 10 years. This is not a continuous appointment.
The inspecting engineer produces a report and directs the undertaker to carry out any required safety measures. These will have deadlines which the undertaker must meet. The inspecting engineer must certify when safety measures are completed.
We provide proactive advice and support about complying with the Act when asked. We also provide advice and guidance on how to comply with the Act if a non-compliance offence is committed. We do this in writing or by meeting the undertakers.
If the offence persists or is serious, we will escalate and take formal enforcement action. When we do this, we follow the Regulators Code. We apply the following principles:
- act proportionately
- be consistent
- be transparent
- target enforcement action
- be accountable
5.1 Risk designation
We assign a risk designation to each LRR in England. The designation level is based on risk to life in the event of an uncontrolled release of water from the reservoir.
There are 2 designation levels:
- high-risk
- not high-risk
High-risk reservoirs must fulfil all the requirements of the Act. There are also some specific elements which ‘not high-risk’ reservoirs must fulfil.
LRRs which are classed as ‘not high-risk’ do not need a:
- supervising engineer appointed
- statutory inspection
Undertakers must still register the not high-risk reservoir, have on-site emergency flood plans and report any incidents. They should inform us if anything changes on site or downstream which might alter the risk designation. These changes could include property developments downstream or alterations to the reservoir.
We assign a risk designation once we receive a final certificate from a construction engineer.
There may be reservoirs which do not yet have a risk designation. This can happen where they have been newly constructed or recently altered. If an undertaker has requested a review or appealed a risk designation, a provisional designation will be put in place.
Table 1: Risk designation status of LRRs
Status on 31 December 2024 | Number of reservoirs |
---|---|
High-risk - including provisional designations | 1,727 |
High-risk - provisional designations | 9 |
High-risk - under construction for alteration | 16 |
Not high-risk | 299 |
Not yet determined - reservoirs under construction | 113 |
Not yet determined - reservoirs in operation | 3 |
Review of designation | 5 |
Appeal of designation | 0 |
Of the 129 reservoirs under construction:
- 78 have a preliminary section 7(1) certificate. This certificate confirms that the reservoir has reached a stage of construction where it can be wholly or partially filled with water
- 40 are not yet ready to be filled with water
- 11 have preliminary certificates under section 8 or 9 of the Act. Section 8 is used when the undertaker hasn’t appointed a construction engineer. Section 9 is used for reinstating an abandoned reservoir. These reservoirs can also be wholly or partially filled with water
5.2 Reservoir information
Table 2: Information received on engineering activities at LRRs from 1 January 2023 to 31 December 2024
Reservoir information recorded | Number of reservoirs |
---|---|
Number of supervising engineers newly appointed by or on behalf of the undertaker | 577 |
Number of certificates issued after the satisfactory completion of an inspection under section 10 of the Act | 309 |
Number of these certificates which contained measures to be taken in the interests of safety | 158 |
Number of section 10(6) certificates showing that measures to be taken in the interests of safety had been satisfactorily completed | 119 |
Reservoirs are inspected by an inspecting engineer every 10 years, unless stipulated otherwise by the supervising engineer. The inspecting engineer produces a certificate under Section 10 of the Act.
In 2023 to2024, 51 % of Section 10 inspection certificates (158 of the 309) contained safety measures. This is a decrease from 56% in 2021-22. The number of inspections taking place and safety measures identified within a two-year window does fluctuate.
The deadlines to complete measures can be more than one to two years. The 119 section 10(6) certificates showing measures have been completed do not necessarily correspond to the 158 certificates which contained measures to be taken in the interests of safety.
Table 3: Total number of reservoirs by undertaker type
Undertaker type | Number of reservoirs | % of total number of reservoirs |
---|---|---|
Water companies | 665 | 31% |
Private landowners and trusts | 359 | 17% |
Farms | 342 | 16% |
Environment Agency | 222 | 10% |
Local authority | 184 | 9% |
Industrial and commercial | 109 | 5% |
Canal & River Trust | 74 | 3% |
National Trust | 44 | 2% |
Registered charities | 46 | 2% |
Recreational clubs and associations | 43 | 2% |
Other government agencies and departments | 40 | 2% |
Fish farms | 13 | 1% |
Universities, colleges and schools | 9 | <1% |
Other/unknown | 17 | 1% |
Note: the total percentage is over 100%, as some reservoirs have multiple undertakers.
There were 34 newly constructed reservoirs recorded between 1 January 2023 and 31 December 2024. These 34 reservoirs have moved from being under construction to in operation.
Twenty-five newly constructed reservoirs had a preliminary section 7(1) certificate.
Table 4: Newly constructed reservoirs by undertaker type
Undertaker type | Number of reservoirs |
---|---|
Farms | 14 |
Water companies | 6 |
Local authority | 5 |
Environment Agency | 4 |
Industrial and commercial | 2 |
Fish farms | 1 |
Other government agencies and departments | 1 |
Recreational clubs and associations | 1 |
Table 5: Risk designations of newly constructed reservoirs
Undertaker Type | High-risk | Not high-risk | Not yet determined |
---|---|---|---|
Farms | 11 | 2 | 1 |
Water companies | 5 | 0 | 1 |
Local authority | 4 | 1 | 0 |
Environment Agency | 4 | 0 | 0 |
Industrial and commercial | 2 | 0 | 0 |
Fish farms | 1 | 0 | 0 |
Other government agencies and departments | 1 | 0 | 0 |
Recreational clubs and associations | 1 | 0 | 0 |
5.3 Compliance figures
High-risk reservoirs must have a supervising engineer appointed at all times. Reservoir engineers have an important role to provide technical and expert advice to reservoir owners.
Table 6: Non compliances from 1 January 2023 to 31 December 2024
Non-compliance status | Situation on 1 January 2023 | Situation on 31 December 2024 |
---|---|---|
Number with no supervising engineer appointed | 2 | 29 (3 with no final risk designation) |
Inspection due, and no inspecting engineer appointed | 5 | 10 |
Section 10 inspection overdue by more than a year, but an inspecting engineer has been appointed | 11 | 10 |
Measures in the interests of safety that have not been completed by the deadline set by the inspecting engineer | 56 | 80 (3 with no final risk designation) |
Reservoirs in operation with no onsite flood plan | 0 | 0 |
The table states where the risk designation for a reservoir is not final. This means that some figures may change in future, as the reservoirs could be determined as not high-risk.
We have included reservoirs where the inspection has taken place, but we have not yet received the report. The Act allows 6 months for an engineer to finalise their report. This contributes to the higher non-compliance figures because we do not know the date of the inspection until we receive the report. The overdue dates will then be updated.
We issue a formal notice when an undertaker fails to appoint an inspecting engineer by the inspection due date. Undertakers must then appoint an engineer within 28 days.
There were 80 reservoirs with outstanding safety measures at the end of 2024. This is an increase from 56 on 1 Jan 2023. Reservoir infrastructure is aging, leading to engineers recommending more safety measures.
Following the Toddbrook incident in 2019, we have seen an increase in the number of measures in the interests of safety (MIOS) related to spillway safety. We have also seen an increase in MIOS to meet the recommendations in the drawdown capacity guidance published in 2017. There is also a shortage of reservoir engineers, which can delay sign-off of safety measures. The ICE published an independent review of reservoir engineer shortages in 2021. Following this, we are addressing the number, skill level and workload of reservoir engineers through the reservoir safety reform programme. This includes steps to increase training and development of engineers.
However, we have confidence in the safety of our reservoirs. We have increased our engagement with owners and engineers to pro-actively mitigate the risks associated with pending non-compliances. We assign an enforcement officer to take proportionate, confident action on all reservoirs with outstanding safety measures. We use a range of enforcement actions. This includes advice and guidance, compliance action plans, serving notices and prosecution.
We are transparent and consistent with how we assess what enforcement action we are taking.
We expect the number of outstanding MIOS to reduce over the next two years.
5.4 Serving enforcement notices
We may serve an enforcement notice if an undertaker does not comply after advice and guidance is given.
We will serve formal notice if an undertaker does not appoint an engineer when required and after reminding. The undertaker must then make the appointment within 28 days.
If an undertaker does not complete safety measures by a given deadline we can:
- ask the undertaker why they have not completed the measures
- issue a Compliance Action Plan if appropriate - any safety risk is mitigated and the undertaker is engaged and capable
- issue a formal notice for completion of the measures if there is no response
- issue a final warning letter if they miss the notice date
- prosecute, if the breach is significant and there are no reasonable mitigating circumstances
We served a total of 81 notices in this reporting period. 19 of these notices (16(1), 17(1), 17(1)(e), 21A) relate to emergency powers, powers of entry and powers to require information, so they may not be directly related to non-compliance. We served notices on 64 non-compliance cases in 2023 and 2024. Of these, 49 cases are now compliant. We continue to monitor and act where necessary on all outstanding cases.
Table 7: Number of notices served 1 January 2023 to 31 December 2024
Section of the Act | Reason for serving notice | Number of notices served |
---|---|---|
Section 6(1) | Failure to appoint a construction engineer | 8 |
Section 8(1) | Failure to appoint a construction engineer | 2 |
Section 10(7)(a) | Failure to appoint an inspecting engineer | 11 |
Section 10(7)(b) | Failure to complete safety measures by stipulated deadline(s) section 10(3) | 4 |
Section 12(4) | Failure to appoint a supervising engineer | 37 |
Section 16(1) | Emergency Powers | 1 |
Section 17(1) | Powers of Entry | 14 |
Section 17(1)(e) | Powers of Entry | 3 |
Section 21A | Power to require information | 1 |
The number of outstanding safety measures in Table 6 is higher than the number of notices served in Table 7. This is because overdue measures do not always need a notice to encourage an undertaker to comply. Often, the non-compliance can be addressed following tailored advice and guidance.
Table 8: Number of notices served by undertaker type
Undertaker type | Total number of notices served |
---|---|
Private landowners and trusts | 40 |
Farms | 8 |
Local authority | 10 |
Industrial and commercial | 9 |
Recreational clubs and associations | 7 |
Other government agencies and departments | 4 |
Fish farms | 1 |
Other/unknown | 2 |
5.5 Other enforcement action
We may issue a written warning if an undertaker remains non-compliant after the notice deadline. We issued two of these warnings between January 2023 and December 2024.
We are currently investigating 108 reservoirs and may take enforcement action depending on the results.
We apply a risk-based approach to achieve the right outcome for safety. This means we have used our professional judgement. We may consult with panel engineers and lawyers to take appropriate action. That action could be to issue advice and guidance or could go as far as carrying out emergency works. We carried out emergency works at 1 reservoir between January 2023 and December 2024.
We take this approach so that we can achieve safe outcomes in line with the Regulators Code. It is not always appropriate for us to take punitive enforcement action if a reservoir becomes non-compliant.
We have continued to monitor and collect data on:
-
offences under section 11(2) – keeping and updating the prescribed form of record
-
offences under section 10(5A) – maintenance measures
We have been collecting this data, however due to its complexity, we will not be including this information in the current report.
We will continue to monitor this data and review the benefit of reporting on this in the next report.
We encourage engineers to highlight any specific concerns about section 11 or 10(5A) non-compliances to us.
5.6 Environment Agency Reservoirs
We are the undertaker for 222 LRRs in England.
There were 6 cases of non-compliance at our reservoirs in 2023 and 2024. Three reservoirs remain non-compliant, including Warnham Mill Pond Reservoir. The Environment Agency is one of three joint undertakers for Warnham Mill Pond Reservoir. The Environment Agency undertaker has met their obligations for the areas that are within our responsibility.
5.7 Incident reporting
Incident reporting became mandatory in 2013. Undertakers must report any reportable incidents which happen at their reservoir. A reportable incident is “an incident which results, or could result, in the uncontrolled release of water from an large raised reservoir.”
This also includes where “measures have been taken to prevent any or any further uncontrolled release of water and to minimise the danger to human life”.
We use this information to improve safety by:
-
investigating incidents where appropriate
-
informing the industry of any trends and important lessons identified
-
contributing to research into reservoir safety and incident analysis
We publish detailed information in our annual post incident report. This means those involved in reservoir safety can learn from past incidents.
Reporting is only mandatory for incidents at LRRs. We encourage undertakers to report incidents at small raised reservoirs on a voluntary basis.
Table 9: Reported incidents
Reported incidents | 2013 | 2014 | 2015 | 2016 | 2017 | 2018 | 2019 | 2020 | 2021 | 2022 | 2023 | 2024 |
---|---|---|---|---|---|---|---|---|---|---|---|---|
Incidents at LRRs | 2 | 8 | 3 | 7 | 8 | 8 | 14 | 9 | 9 | 10 | 20 | 12 |
Incidents at small raised reservoirs | 1 | 0 | 0 | 0 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 0 |
Total number of reported incidents | 3 | 8 | 3 | 7 | 9 | 9 | 15 | 10 | 10 | 11 | 21 | 12 |
We expect the number of incident reports to increase in the future. This is not necessarily because more incidents are happening, but that we expect to receive more as the reporting culture improves. We are working to raise awareness of the benefits that incident reporting brings.
We continue to encourage undertakers to report all incidents, and near misses. We have not taken enforcement action to obtain incident reports, but we have issued reminders to undertakers where a report is due. Compliance with the regulations on incident reporting is generally seen to be good and improving.
Some of these figures may have been different in previous reports. It is likely that this is due to discrepancies with what has been classed as an incident or near miss during the different time periods. The figures in table 9 are correct up to 2022, however 2023 and 2024 figures may change. This is because reservoir undertakers have 12 months after an incident to provide us with a full post-incident report.
6. The future
We will continue to explore digital innovation to improve ways of working. We will create efficiencies and improve data quality and consistency. This includes working with specialised digital teams to adopt these new technologies. We hope to use artificial intelligence to improve how we work and the experiences of our users.
We would like to improve our transparency and collaboration with the industry. We will communicate and engage more with undertakers, engineers and professional institution partners.
We will continue to take firm action against those whose performance puts public safety at risk. We will ensure that regulation translates into compliance and that serious non-compliance is held to account.
Climate change is an important topic, posing a significant risk to the reservoir industry. In 2025, we will be reviewing and updating our research strategy. We will evaluate how we can better support the industry’s research needs considering climate change, and other emerging threats. We will continue to deliver research through the Defra and Environment Agency joint programme.
We will maintain our work on our reservoir reform programme and provide regular updates.
7. Appendix 1: Reservoir data and statistics
This report has previously shown reservoir data from 2005 to present. We have changed the tables to show only the past 10 years of data and information. If you are interested in data from before 2015, you can access this in the 2021 to 2022 report.
7.1 Dam category
Although not legally required, a reservoir construction or inspecting engineer should assign a dam category to an impounding LRR as best practice. The category the engineer assigns depends on potential consequences of a dam breach. The dam category assigned is based on ICE guidance for reservoir flood spillway design and takes a risk-based approach to reservoir design and inspections.
Table 10 distribution of dam category as of 31 December 2024
Dam Category | Number of LRRs | % of total number of LRRs |
---|---|---|
A | 899 | 42% |
B | 375 | 18% |
C | 481 | 22% |
D | 203 | 9% |
Not assigned | 68 | 3% |
Not known | 116 | 5% |
Total | 2,142 |
In table 10, a:
- category A dam is where a breach could endanger lives in a community
- category B dam is where a breach could endanger lives not in a community or could result in extensive damage
- category C dam is where a breach would pose negligible risk to life and cause limited damage
- category D dam - special cases where no loss of life can be foreseen as a result of a breach and very limited additional flood damage would be caused
- ‘not assigned’ case is where in some cases, engineers have not assigned a dam category yet- majority of these are non-impounding and service reservoirs
Before July 2013 engineers did not need to submit to us copies of section 10 reports that did not contain safety measures. The ‘not known’ category refers to where dam categories may not be available for some reservoirs. This category also includes reservoirs under construction where the dam category is yet to be determined. This number is reducing as we receive new reports.
Table 11: Number and type of English LRRs from 31 March 2005 to 31 December 2024
Description | 2 Jan 2015 | 31 Dec 2016 | 31 Dec 2018 | 31 Dec 2020 | 31 Dec 2022 | 31 Dec 2023 | 31 Dec 2024 |
---|---|---|---|---|---|---|---|
Total no. LRRs | 2001 | 2020 | 2055 | 2097 | 2117 | 2133 | 2142 |
Number reservoirs under construction | 167 | 145 | 118 | 133 | 130 | 139 | 129 |
No. abandoned reservoirs | 3 | 3 | 4 | 2 | 2 | 2 | 2 |
No. discontinued reservoirs | 225 | 235 | 253 | 262 | 271 | 277 | 280 |
No. proposed reservoirs | 59 | 64 | 78 | 76 | 79 | 83 | 84 |
Total no. undertakers | 772 | 847 | 839 | 838 | 851 | 852 | 858 |
Total no. EA reservoirs | 209 | 211 | 214 | 219 | 219 | 221 | 222 |
In Table 11:
- LRRs are reservoirs that are in operation, abandoned, and under construction
- under construction reservoirs - includes both new reservoirs and those being altered
- abandoned reservoirs – although empty, an abandoned reservoir is still capable of holding at least 25,000 cubic metres of water above natural ground level
- discontinued reservoirs – the discontinuance of a dam, requires an undertaker to reduce a reservoir’s capacity to a volume that is less than 25,000 cubic metres
- proposed reservoirs - are locations at which an LRR may be constructed in the future
- Environment Agency reservoirs - comprises those reservoirs that are in operation, abandoned, and under construction
Table 12: Supervising engineer appointments
Description | 2 Jan 2015 | 31 Dec 2016 | 31 Dec 2018 | 31 Dec 2020 | 31 Dec 2022 | 31 Dec 2024 |
---|---|---|---|---|---|---|
Number of LRRs with no supervising engineer | 8 | 8 | 3 | 5 | 2 | 29 |
In Table 12 the figures for 2020 do not include 10 LRRs which were awaiting risk designation.
Table 13: Inspecting engineer (IE) appointments
Description | 2 Jan 2015 | 31 Dec 2016 | 31 Dec 2018 | 31 Dec 2020 | 31 Dec 2022 | 31 Dec 2024 |
---|---|---|---|---|---|---|
Number of LRRs for which the next section 10 inspection (S10) report is overdue | 76 | 91 | 105 | 70 | 69 | 71 |
Number of LRRs for which the next S10 inspection report is overdue for at least one year, for which an inspection and report is underway (an IE has been appointed) | 14 | 7 | 12 | 5 | 11 | 10 |
Number of LRRs for which the next S10 inspection report is overdue for less than one year, for which an inspection and report is underway (an IE has been appointed) | 48 | 71 | 85 | 62 | 54 | 51 |
Number of LRRs for which the next S10 inspection has been overdue for at least one year, for which an IE has NOT been appointed | 0 | 4 | 0 | 1 | 0 | 8 |
Number of LRRs for which the next S10 inspection has been overdue for less than one year for which an IE has NOT been appointed | 14 | 9 | 8 | 2 | 4 | 2 |
All high-risk reservoirs must be inspected periodically by an inspecting engineer, at intervals no greater than 10 years. On 31 December 2024 there were 71 reservoirs with an overdue section 10 inspection. Of these:
- 61 had an overdue S10 inspection report, but they had appointed an inspecting engineer. This means that a report and inspection was underway. 51 of these had been overdue for under a year and 10 had been overdue for at least a year
- 10 had an S10 inspection overdue and they had not appointed an inspecting engineer. 2 of these had been overdue for under a year and 8 had been overdue for at least a year
- the figures may include reservoirs awaiting a risk designation
Table 14: Measures to be taken in the interest of safety (MIOS)
Description | 2 Jan 2015 | 31 Dec 2016 | 31 Dec 2018 | 31 Dec 2020 | 31 Dec 2022 | 31 Dec 2024 |
---|---|---|---|---|---|---|
Number of LRRs with MIOS | 172 | 272 | 196 | 268 | 243 | 253 |
Number of LRRs with overdue MIOS | 36 | 57 | 49 | 65 | 56 | 80 |
MIOS are essential works identified by an inspecting engineer during part of a section 10 inspection. The undertaker is legally required to implement MIOS.
Reservoirs with MIOS are not necessarily non-compliant. 253 is the total number of reservoirs that had safety measures identified at the end of 2024. Only 80 of these have safety measures that are overdue beyond their target date.
There has been an increase in the number of outstanding safety measures from 36 on 2 Jan 2015 to 80 at the end of 2024. Reservoir infrastructure is aging, leading to engineers recommending more safety measures. Following the Toddbrook incident in 2019, we have seen an increase in the number of MIOS related to spillway safety. We have also seen an increase in MIOS to meet the recommendations in the drawdown capacity guidance published in 2017. The ICE published an independent review of the supply and capacity of reservoir safety panel engineers in 2021. Following this, we are addressing the number, skill level and workload of reservoir engineers through the reservoir safety reform programme. This includes steps to increase training and development of engineers.
We have previously reported on MIOS without a target date. It is no longer possible to have MIOS without a target date. The number of LRRs with MIOS for which there is no target date will continue to be 0 from now on.
8. Appendix 2: Steps taken by the enforcement authority to ensure that undertakers observe and comply with the requirements of the act
The Environment Agency refers to sections of the Act in appendix 2. The notices listed refer to:
-
section 8(1) ‘Powers of enforcement authority in event of non-compliance with requirements as to construction or enlargement of reservoirs’ – the offence is failure to appoint a construction engineer
-
section 10(7)(a) ‘Periodical inspection of large raised reservoirs’ – the offence is failure to appoint an inspecting engineer
-
section 10(7)(b) ‘Periodical inspection of large raised reservoirs’ – the offence is that the latest Section 10 report contains safety recommendations and a date by which these must be done and the work has not been done as required or by the date required
-
section 12A ‘flood plans: large raised reservoirs’ – this offence is that an undertaker has not provided a 12AA(3) certificate and 12AA(4) direction which is a legal requirement
-
section 12(4) ‘Supervision of large raised reservoirs’ – the offence is failure to appoint a supervising engineer
-
section 16(4) ‘Emergency powers’ – this notice tells the undertaker what measures we are taking in exercising our emergency powers
-
section 17(1)(e) ‘Powers of Entry’ – this notice authorises a person to enter the land relating to a reservoir on behalf of the Environment Agency
-
section 21A ‘Power to require information’ – this notice requires the undertaker to provide information specified in the notice within a specified timeframe
8.1 Data protection
The Environment Agency have listed those undertakers that are limited companies and public sector organisations. The Data Protection Act 1998 does not permit us to publish the names of private individuals - including partnerships and sole traders.
Albany Park River Restoration and Flood Alleviation Scheme
Undertaker: London Borough of Enfield
Undertaker Type: local authority
Relevant section of the act: 6(1)
Offence: failure to appoint a construction engineer
Enforcement action: notice served
Compliance status on 31 December 2024: compliant
Aldenham
Undertaker: Jewel of Hertsmere Ltd
Undertaker Type: industrial and commercial
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
Aldenham
Undertaker: Jewel of Hertsmere Ltd
Undertaker Type: industrial and commercial
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: notice served
Compliance status on 31 December 2024: compliant
Aldermaston Court Lake
Undertaker: Dove Crag Limited
Undertaker Type: other/unknown
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Alexandra
Undertaker: S.H.L Properties and Investments Ltd
Undertaker Type: industrial and commercial
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Arlington
Undertaker: South East Water Ltd
Undertaker Type: water companies
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
Barkers Farm
Undertaker: S R Lewin
Undertaker Type: farms
Relevant section of the act: 6(1)
Offence: failure to appoint a construction engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Barr Beacon 2
Undertaker: South Staffordshire Water PLC
Undertaker Type: water companies
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
Barrow Compensation
Undertaker: Bristol Water Plc
Undertaker Type: water companies
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Basin Pond
Undertaker: Bedford Estates Nominees Ltd
Undertaker Type: private landowners and trusts
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
Bedgebury Park Great Lake
Undertaker: Columbia International SA
Undertaker Type: other/unknown
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: notice served
Compliance status on 31 December 2024: compliant
Berners Hall Farm
Undertaker: Essex Farms Ltd
Undertaker Type: farms
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
Berrington Pool
Undertaker: The National Trust
Undertaker Type: national trust
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Bewl Water
Undertaker: Southern Water Services Ltd
Undertaker Type: water companies
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
Birkacre
Undertaker: Chorley Borough Council
Undertaker Type: local authority
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Birney Hill
Undertaker: Northumbrian Water Limited
Undertaker Type: water companies
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Birtle Upper
Undertaker: Pinnacle Living 2 Ltd
Undertaker Type: industrial and commercial
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: notice served
Compliance status on 31 December 2024: non-compliant
Birtle Upper
Undertaker: Pinnacle Living 2 Ltd
Undertaker Type: industrial and commercial
Relevant section of the act: 10(7)(b) leading to 17(1)(e) action
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: notice served
Compliance status on 31 December 2024: non-compliant
Blithfield
Undertaker: South Staffordshire Water Plc
Undertaker Type: water companies
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
Blue Barn Reservoir
Undertaker: New Shoots Limited
Undertaker Type: farms
Relevant section of the act: 6(1)
Offence: failure to appoint a construction engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Bockingham Hall
Undertaker: Cottrell Fund - Round 1969 Settlement
Undertaker Type: private landowners and trusts
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Bolton Lower Reservoir
Undertaker: A & H Haulage Ltd
Undertaker Type: industrial and commercial
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Bootham Lane SRC Lagoons
Undertaker: BDR Waste Disposal Ltd
Undertaker Type: other/unknown
Relevant section of the act: 6(1)
Offence: failure to appoint a construction engineer
Enforcement action: notice served
Compliance status on 31 December 2024: compliant
Bosworth Water Trust Amenity Lake
Undertaker: Bosworth Water Trust
Undertaker Type: private landowners and trusts
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
Bramshill House Pond
Undertaker: Bramshill House Limited
Undertaker Type: private landowners and trusts
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: notice served
Compliance status on 31 December 2024: compliant
Brindley Ford Flood Storage Reservoir
Undertaker: The Coal Authority
Undertaker Type: industrial and commercial
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
Bromfield Middle Pool
Undertaker: Trustees of the Plymouth Settled Estate
Undertaker Type: private landowners and trusts
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
Bromfield Upper Pool
Undertaker: Trustees of the Plymouth Settled Estate
Undertaker Type: private landowners and trusts
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Brook Farm Upper
Undertaker: Brook Farms Ltd
Undertaker Type: farms
Relevant section of the act: 6(1)
Offence: failure to appoint a construction engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
Buckshole
Undertaker: Hastings Borough Council
Undertaker Type: local authority
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Burghley House Lake
Undertaker: Burghley House Preservation Trust Ltd
Undertaker Type: registered charities
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Buscot Park Lake
Undertaker: The National Trust
Undertaker Type: The National Trust
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Butlers Leap
Undertaker: Rugby Borough Council
Undertaker Type: local authority
Relevant section of the act: 8(1)
Offence: failure to appoint a construction engineer
Enforcement action: notice served
Compliance status on 31 December 2024: compliant
Butlers Leap
Undertaker: Rugby Borough Council
Undertaker Type: local authority
Relevant section of the act: 8(3)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Caen Hill Marina
Undertaker: Geomac Ltd
Undertaker Type: recreational clubs and associations
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Caen Hill Marina
Undertaker: Geomac Ltd
Undertaker Type: recreational clubs and associations
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: notice served
Compliance status on 31 December 2024: compliant
Carburton
Undertaker: The Welbeck Estates Co. Ltd
Undertaker Type: private landowners and trusts
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Carburton
Undertaker: The Welbeck Estates Co. Ltd
Undertaker Type: private landowners and trusts
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Carburton Forge
Undertaker: The Welbeck Estates Co. Ltd
Undertaker Type: private landowners and trusts
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Carburton Forge
Undertaker: The Welbeck Estates Co. Ltd
Undertaker Type: private landowners and trusts
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Carr Hill Reservoir
Undertaker: Northumbrian Water Limited
Undertaker Type: water companies
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
Cartgate FSR
Undertaker: The Highways Agency Operations Directorate
Undertaker Type: other government agencies and departments
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Castle Acre
Undertaker: Holkham Farming Company Ltd
Undertaker Type: farms
Relevant section of the act: 8(1)
Offence: failure to appoint a construction engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Castle Acre
Undertaker: Holkham Farming Company Ltd
Undertaker Type: farms
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Chard
Undertaker: South Somerset District Council
Undertaker Type: local authority
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
Cheddar
Undertaker: Bristol Water Plc
Undertaker Type: water companies
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
Cherry Orchard (Poplars Reservoir)
Undertaker: CH Cole & Sons
Undertaker Type: farms
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Cheshunt North FSA
Undertaker: Environment Agency
Undertaker Type: Environment Agency
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
Chilling 2 Reservoir
Undertaker: Barfoot Farms Limited
Undertaker Type: farms
Relevant section of the act: 8(1)
Offence: failure to appoint a construction engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Chingford Pond
Undertaker: Petworth Management Company Limited
Undertaker Type: private landowners and trusts
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Church Reservoir (Childerditch Hall Lower)
Undertaker: Childerditch Hall Farm Nominees Limited
Undertaker Type: farms
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
Cobrey Farm Reservoir
Undertaker: Cobrey Farms
Undertaker Type: farms
Relevant section of the act: 6(1)
Offence: failure to appoint a construction engineer
Enforcement action: notice served
Compliance status on 31 December 2024: compliant
College Farm Reservoir, Duxford
Undertaker: Russell Smith Farms Limited
Undertaker Type: farms
Relevant section of the act: 8(3)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
College Farm Reservoir, Duxford
Undertaker: Russell Smith Farms Limited
Undertaker Type: farms
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
Colt Crag
Undertaker: Northumbrian Water Limited
Undertaker Type: water companies
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Coningsby (ID173)
Undertaker: G S Haines and Sons
Undertaker Type: farms
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
Coombe Bank Lake
Undertaker: Lynxtrade UK Limited
Undertaker Type: recreational clubs and associations
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Coombe Pool
Undertaker: COVENTRY CITY COUNCIL
Undertaker Type: local authority
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
Cove Brook FSR
Undertaker: Environment Agency
Undertaker Type: Environment Agency
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
Cransley Waters
Undertaker: Cransley Reservoir Wildlife Reserve CIC
Undertaker Type: recreational clubs and associations
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Crowthorne Service Reservoir (Cells 2 & 3)
Undertaker: South East Water Ltd
Undertaker Type: water companies
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Culverthorpe Lower Lake
Undertaker: JR Clark Limited
Undertaker Type: private landowners and trusts
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: notice served
Compliance status on 31 December 2024: non-compliant
Culverthorpe Lower Lake
Undertaker: JR Clark Limited
Undertaker Type: private landowners and trusts
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Dartridge (at Childerditch Hall)
Undertaker: Childerditch Hall Farm Nominees Limited
Undertaker Type: farms
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
Decoy Farm Reservoir
Undertaker: New Shoots Limited
Undertaker Type: farms
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Dernford
Undertaker: Russell Smith Farms Limited
Undertaker Type: farms
Relevant section of the act: 8(3)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Dernford
Undertaker: Russell Smith Farms Limited
Undertaker Type: farms
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
Dreamfields (ID370)
Undertaker: Alan Firmin Limited
Undertaker Type: farms
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Drunkard’s Lane reservoir
Undertaker: G.H. & J.G. Paul
Undertaker Type: farms
Relevant section of the act: 6(1)
Offence: failure to appoint a construction engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
Durngate Flood Alleviation Reservoir
Undertaker: Winchester City Council
Undertaker Type: local authority
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
East Fen Farm
Undertaker: East Fen Farms Limited
Undertaker Type: farms
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
East Kettering Attenuation Pond
Undertaker: Hanwood Park LLP
Undertaker Type: private landowners and trusts
Relevant section of the act: 10(7)(a)
Offence: failure to appoint an inspecting engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
East Mere Irrigation Reservoir
Undertaker: Patrick Dean Ltd
Undertaker Type: farms
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Eccleston Mere
Undertaker: Pheasant Equities Limited
Undertaker Type: private landowners and trusts
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: notice served
Compliance status on 31 December 2024: non-compliant
Eccleston Mere
Undertaker: Pheasant Equities Limited
Undertaker Type: private landowners and trusts
Relevant section of the act: 10(7)(a)
Offence: failure to appoint an inspecting engineer
Enforcement action: notice served
Compliance status on 31 December 2024: non-compliant
Edgar Farm Reservoir
Undertaker: Walsingham Estate Farming Ltd
Undertaker Type: farms
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Etherow Country Park
Undertaker: Stockport Borough Council
Undertaker Type: local authority
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: notice served
Compliance status on 31 December 2024: non-compliant
Etherow Country Park
Undertaker: Stockport Borough Council
Undertaker Type: local authority
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Factory Hill Reservoir
Undertaker: Wilkin & Sons Ltd
Undertaker Type: industrial and commercial
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
Fiddler’s Ferry P.S. Ash Lagoon A
Undertaker: Peel Land & Property Ltd
Undertaker Type: private landowners and trusts
Relevant section of the act: 10(7)(a)
Offence: failure to appoint an inspecting engineer
Enforcement action: notice served
Compliance status on 31 December 2024: compliant
Fiddler’s Ferry P.S. Ash Lagoon B
Undertaker: Peel Land & Property Ltd
Undertaker Type: private landowners and trusts
Relevant section of the act: 10(7)(a)
Offence: failure to appoint an inspecting engineer
Enforcement action: notice served
Compliance status on 31 December 2024: compliant
Fiddler’s Ferry P.S. Ash Lagoon D
Undertaker: Peel Land & Property Ltd
Undertaker Type: private landowners and trusts
Relevant section of the act: 10(7)(a)
Offence: failure to appoint an inspecting engineer
Enforcement action: notice served
Compliance status on 31 December 2024: compliant
Fish Pond (Lake View)
Undertaker: Aquamaintain Ltd
Undertaker Type: fish farms
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
Foxenfield
Undertaker: Abbots Ripton Farming Company
Undertaker Type: farms
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
Franks Farm reservoir
Undertaker: W.B. Chambers Farms Ltd
Undertaker Type: farms
Relevant section of the act: 6(1)
Offence: failure to appoint a construction engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
Frensham Great Pond
Undertaker: Waverley Borough Council
Undertaker Type: local authority
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Gatton Park Lake
Undertaker: The Royal Alexandra & Albert School
Undertaker Type: private landowners and trusts
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
Grange Farm Westleton
Undertaker: Ward Farming Limited
Undertaker Type: farms
Relevant section of the act: 6(1)
Offence: failure to appoint a construction engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Grantham Covered Anaerobic Lagoon
Undertaker: McCain Foods (GB) Ltd
Undertaker Type: industrial and commercial
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Graysmoor Winter Storage Reservoir
Undertaker: AgReserves Limited
Undertaker Type: farms
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Great Island Pond
Undertaker: Longleat Estates
Undertaker Type: private landowners and trusts
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Great Lake
Undertaker: The Welbeck Estates Co. Ltd
Undertaker Type: private landowners and trusts
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Great Lake
Undertaker: The Welbeck Estates Co. Ltd
Undertaker Type: private landowners and trusts
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Great Sir Hughes (ID144)
Undertaker: GSH Farming Ltd
Undertaker Type: farms
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Green Lane Reservoir
Undertaker: Heygate Farms Swaffham Ltd
Undertaker Type: farms
Relevant section of the act: 10(7)(a)
Offence: failure to appoint an inspecting engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Green Mile Farm
Undertaker: Green Mile Farm Ltd (Formerly J C M Glassford Ltd)
Undertaker Type: farms
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Groby Pool
Undertaker: Hanson Plc
Undertaker Type: industrial and commercial
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
H7 Reservoir
Undertaker: Barfoot Farms Limited
Undertaker Type: farms
Relevant section of the act: 8(1)
Offence: failure to appoint a construction engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Haigh Cote
Undertaker: Halifax Water Ski Club
Undertaker Type: industrial and commercial
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Half Mile Pond
Undertaker: Longleat Estates
Undertaker Type: private landowners and trusts
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Hardwick Hall Lake
Undertaker: DURHAM COUNTY COUNCIL
Undertaker Type: local authority
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
Harlaxton Manor Upper Lake
Undertaker: Harlaxton College
Undertaker Type: other government agencies and departments
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
Harthill
Undertaker: Canal & River Trust
Undertaker Type: Canal & River Trust
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Hazlewood
Undertaker: Blackheath Farms Limited
Undertaker Type: farms
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Heapey No.1
Undertaker: Wigan & District Angling Association
Undertaker Type: recreational clubs and associations
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: notice served
Compliance status on 31 December 2024: compliant
Heapey No.2
Undertaker: Wigan & District Angling Association
Undertaker Type: recreational clubs and associations
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: notice served
Compliance status on 31 December 2024: compliant
Heapey No.3
Undertaker: Wigan & District Angling Association
Undertaker Type: recreational clubs and associations
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: notice served
Compliance status on 31 December 2024: compliant
Hemlington Lake
Undertaker: MIDDLESBROUGH COUNCIL
Undertaker Type: local authority
Relevant section of the act: 10(7)(a)
Offence: failure to appoint an inspecting engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Hewell Grange
Undertaker: HM Prison Service
Undertaker Type: other government agencies and departments
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Hicks Lodge Upper Pond
Undertaker: Forestry Commission
Undertaker Type: other government agencies and departments
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
High Dam
Undertaker: Lake District National Park Authority
Undertaker Type: other government agencies and departments
Relevant section of the act: 10(7)(a)
Offence: failure to appoint an inspecting engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Highfield Farm Reservoir
Undertaker: Raveningham Farms Limited
Undertaker Type: farms
Relevant section of the act: 6(1)
Offence: failure to appoint a construction engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Highmoor Drove
Undertaker: JW Spencer Farms Limited
Undertaker Type: farms
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Holland Wood
Undertaker: Abbots Ripton Farming Company
Undertaker Type: farms
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
Horsemoor Reservoir
Undertaker: Woburn Enterprises Limited
Undertaker Type: private landowners and trusts
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
Hullgate Farm
Undertaker: South Pickenham Estate Company Ltd
Undertaker Type: farms
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Kemsley Mill Lagoon No.1
Undertaker: DS Smith Paper Limited
Undertaker Type: industrial and commercial
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Kielder
Undertaker: Northumbrian Water Limited
Undertaker Type: water companies
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
Kives Farm No 1 Reservoir
Undertaker: The Summer Berry Company UK
Undertaker Type: farms
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Kylnclough (Bottom Lodge)
Undertaker: Prince Albert Angling Society
Undertaker Type: recreational clubs and associations
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Kylnclough (Top Lodge)
Undertaker: Prince Albert Angling Society
Undertaker Type: recreational clubs and associations
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
La Serra No.1 Reservoir
Undertaker: La Serra Ltd
Undertaker Type: farms
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Lake Superior
Undertaker: Cornbury Maintenance Company Limited
Undertaker Type: private landowners and trusts
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: notice served
Compliance status on 31 December 2024: compliant
Lime Tree Farm No. 1 Reservoir
Undertaker: New Shoots Limited
Undertaker Type: farms
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Lodgerail Pool
Undertaker: KGL Estates Ltd
Undertaker Type: private landowners and trusts
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
Louth Northern Reservoir
Undertaker: Environment Agency
Undertaker Type: Environment Agency
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Louth Southern Reservoir
Undertaker: Environment Agency
Undertaker Type: Environment Agency
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Lower Drakeloe Pond
Undertaker: Bedford Estates Nominees Ltd
Undertaker Type: private landowners and trusts
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
Lower Ormsgill
Undertaker: Barrow in Furness Borough Council
Undertaker Type: local authority
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Lucerne Lake
Undertaker: Ilchester Estates
Undertaker Type: private landowners and trusts
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
Lucerne Lake
Undertaker: Ilchester Estates
Undertaker Type: private landowners and trusts
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Luton Hoo Lake Lower
Undertaker: Luton Hoo Park Limited
Undertaker Type: private landowners and trusts
Relevant section of the act: 10(7)(a)
Offence: failure to appoint an inspecting engineer
Enforcement action: notice served
Compliance status on 31 December 2024: non-compliant
Luton Hoo Lake Upper
Undertaker: Luton Hoo Park Limited
Undertaker Type: private landowners and trusts
Relevant section of the act: 10(7)(a)
Offence: failure to appoint an inspecting engineer
Enforcement action: notice served
Compliance status on 31 December 2024: non-compliant
Main Lake, Eridge Park
Undertaker: The Nevill Estate Company Limited
Undertaker Type: farms
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: notice served
Compliance status on 31 December 2024: compliant
Malham Tarn
Undertaker: The National Trust
Undertaker Type: The National Trust
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Manor Farm No 3 Reservoir
Undertaker: The Summer Berry Company UK
Undertaker Type: farms
Relevant section of the act: 6(1)
Offence: failure to appoint a construction engineer
Enforcement action: notice served
Compliance status on 31 December 2024: compliant
Manor Farm No 4 Reservoir
Undertaker: The Summer Berry Company UK
Undertaker Type: farms
Relevant section of the act: 6(1)
Offence: failure to appoint a construction engineer
Enforcement action: notice served
Compliance status on 31 December 2024: compliant
Manor Pool (ID355)
Undertaker: Delamere Manor Events Limited
Undertaker Type: industrial and commercial
Relevant section of the act: 10(7)(a)
Offence: failure to appoint an inspecting engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Marlbrook Quarry Landfill
Undertaker: Link Property Developments Ltd
Undertaker Type: private landowners and trusts
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: notice served
Compliance status on 31 December 2024: compliant
Marsh Farm Bund (Ross-on-Wye FSR)
Undertaker: Herefordshire Council
Undertaker Type: local authority
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Marsh Farm Bund (Ross-on-Wye FSR)
Undertaker: Herefordshire Council
Undertaker Type: local authority
Relevant section of the act: 10(7)(a)
Offence: failure to appoint an inspecting engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Marsh Leys Farm - Pond D2
Undertaker: Bedford Borough Council
Undertaker Type: local authority
Relevant section of the act: 6(1)
Offence: failure to appoint a construction engineer
Enforcement action: notice served
Compliance status on 31 December 2024: compliant
Melbourne Pool
Undertaker: Melbourne Estate
Undertaker Type: private landowners and trusts
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Melbury Park Lake
Undertaker: Ilchester Estates
Undertaker Type: private landowners and trusts
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
Melbury Park Lake
Undertaker: Ilchester Estates
Undertaker Type: private landowners and trusts
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Middleton St George Reservoir (Fighting Cocks Reservoir)
Undertaker: Middleton St. George Parish Council
Undertaker Type: other government agencies and departments
Relevant section of the act: 8(3)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
Middleton St George Reservoir (Fighting Cocks Reservoir)
Undertaker: Middleton St. George Parish Council
Undertaker Type: other government agencies and departments
Relevant section of the act: 8(1)
Offence: failure to appoint a construction engineer
Enforcement action: notice served
Compliance status on 31 December 2024: compliant
Mitford Flood Storage Reservoir (Morpeth FSR)
Undertaker: Environment Agency
Undertaker Type: Environment Agency
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Moneystone Quarry
Undertaker: Abbeydale Building Environment Consultants
Undertaker Type: industrial and commercial
Relevant section of the act: 8(1)
Offence: failure to appoint a construction engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Note: this reservoir has a new undertaker. The reservoir was non-compliant when Abbeydale Building Environment Consultants was the undertaker.
Moneystone Quarry
Undertaker: Abbeydale Building Environment Consultants
Undertaker Type: industrial and commercial
Relevant section of the act: 2(2B)
Offence: failure to register a large raised reservoir
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Note: this reservoir has a new undertaker. The reservoir was non-compliant when Abbeydale Building Environment Consultants was the undertaker.
Monkton Farm Irrigation Reservoir
Undertaker: Withers Fruit Farm Ltd
Undertaker Type: farms
Relevant section of the act: 6(1)
Offence: failure to appoint a construction engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Moss Eccles Tarn
Undertaker: The National Trust
Undertaker Type: The National Trust
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
Mytchett Lake
Undertaker: Surrey County Council
Undertaker Type: local authority
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
Newdale Brook Flood Detention Pond
Undertaker: Homes England
Undertaker Type: other government agencies and departments
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
Norton Fitzwarren Dam
Undertaker: BDW Trading Limited (formerly Barratt Homes)
Undertaker Type: industrial and commercial
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: notice served
Compliance status on 31 December 2024: compliant
Nostell Priory Middle Lake
Undertaker: The National Trust
Undertaker Type: The National Trust
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Oil Well Reservoir (ID180)
Undertaker: Glentworth Scottish Farms Limited
Undertaker Type: farms
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
Old Bury Hill Lake
Undertaker: Bury Hill Fisheries
Undertaker Type: fish farms
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Osborne’s Pond
Undertaker: Derbyshire County Council, Station Young (Shipley) Ltd
Undertaker Type: local authority, industrial and commercial
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Overstone Park Lake
Undertaker: Overstone Park Ltd
Undertaker Type: industrial and commercial
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
Park Reservoir
Undertaker: Curley’s Fisheries Ltd
Undertaker Type: fish farms
Relevant section of the act: 12A
Offence: failure to submit onsite flood plan certificates by deadline
Enforcement action: prosecution
Compliance status on 31 December 2024: compliant
Park Reservoir
Undertaker: Curley’s Fisheries Ltd
Undertaker Type: fish farms
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: notice served
Compliance status on 31 December 2024: compliant
Perry Pool
Undertaker: Birmingham City Council
Undertaker Type: local authority
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Pilsworth Reservoir
Undertaker: Lakehaus (N/W) Ltd
Undertaker Type: private landowners and trusts
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: notice served
Compliance status on 31 December 2024: compliant
Pitsea Leachate Lagoon
Undertaker: Veolia Environmental Services (UK) PLC
Undertaker Type: industrial and commercial
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: notice served
Compliance status on 31 December 2024: compliant
Pond Lye
Undertaker: Sussex Piscatorial Society Limited
Undertaker Type: private landowners and trusts
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: notice served
Compliance status on 31 December 2024: compliant
Pontefract Park Lake
Undertaker: Wakefield Council
Undertaker Type: local authority
Relevant section of the act: 8(3)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
Pools Farm Reservoir No. 2
Undertaker: Trustees of the Plymouth Settled Estate
Undertaker Type: private landowners and trusts
Relevant section of the act: 8(3)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Ragley Hall Lake
Undertaker: Marquess of Hertford
Undertaker Type: private landowners and trusts
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Redgrave Pinsent Rowing Lake
Undertaker: The Sports Council Trust Company
Undertaker Type: registered charities
Relevant section of the act: 8(1)
Offence: failure to appoint a construction engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Redhill Farm
Undertaker: Cobrey Farms
Undertaker Type: farms
Relevant section of the act: 6(1)
Offence: failure to appoint a construction engineer
Enforcement action: notice served
Compliance status on 31 December 2024: compliant
Redwalls Lower (ID283)
Undertaker: Alan Firmin Limited
Undertaker Type: farms
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Redwalls Upper (ID369)
Undertaker: Alan Firmin Limited
Undertaker Type: farms
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Reeders Reservoir
Undertaker: The Trustees of No.2 Settlement
Undertaker Type: farms
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Reservoir A
Undertaker: private individual
Undertaker Type: private individual
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: warning letter
Compliance status on 31 December 2024: non-compliant
Reservoir AA
Undertaker: private individual
Undertaker Type: private individual
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
Reservoir AB
Undertaker: private individual
Undertaker Type: private landowners and trusts
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
Reservoir AC
Undertaker: private individual
Undertaker Type: private individual
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: notice served
Compliance status on 31 December 2024: non-compliant
Reservoir AC
Undertaker: private individual
Undertaker Type: private individual
Relevant section of the act: 10(7)(a)
Offence: failure to appoint an inspecting engineer
Enforcement action: notice served
Compliance status on 31 December 2024: non-compliant
Reservoir AD
Undertaker: private individual
Undertaker Type: private individual
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: notice served
Compliance status on 31 December 2024: non-compliant
Reservoir AD
Undertaker: private individual
Undertaker Type: private individual
Relevant section of the act: 10(7)(a)
Offence: failure to appoint an inspecting engineer
Enforcement action: notice served
Compliance status on 31 December 2024: non-compliant
Reservoir AE
Undertaker: private individual
Undertaker Type: private landowners and trusts
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
Reservoir AF
Undertaker: private individual
Undertaker Type: farms
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Reservoir AG
Undertaker: private individual
Undertaker Type: private landowners and trusts
Relevant section of the act: 8(1)
Offence: failure to appoint a construction engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Reservoir AH
Undertaker: private individual
Undertaker Type: private landowners and trusts
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Reservoir AI
Undertaker: private individual
Undertaker Type: private landowners and trusts
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Reservoir AJ
Undertaker: private individual
Undertaker Type: farms
Relevant section of the act: 10(7)(a)
Offence: failure to appoint an inspecting engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
Reservoir AJ
Undertaker: private individual
Undertaker Type: farms
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Reservoir AK
Undertaker: private individual
Undertaker Type: private individual
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Reservoir AL
Undertaker: private individual
Undertaker Type: private landowners and trusts
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Reservoir AM
Undertaker: private individual
Undertaker Type: private landowners and trusts
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: notice served
Compliance status on 31 December 2024: compliant
Reservoir AN
Undertaker: private individual
Undertaker Type: private individual
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Reservoir AO
Undertaker: private individual
Undertaker Type: private landowners and trusts
Relevant section of the act: 10(7)(a)
Offence: failure to appoint an inspecting engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Reservoir AP
Undertaker: private individual
Undertaker Type: farms
Relevant section of the act: 6(1)
Offence: failure to appoint a construction engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
Reservoir AQ
Undertaker: private individual
Undertaker Type: private landowners and trusts
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: notice served
Compliance status on 31 December 2024: compliant
Reservoir AR
Undertaker: private individual
Undertaker Type: farms
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: notice served
Compliance status on 31 December 2024: compliant
Reservoir AS
Undertaker: private individual
Undertaker Type: farms
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: notice served
Compliance status on 31 December 2024: compliant
Reservoir AT
Undertaker: private individual
Undertaker Type: private landowners and trusts
Relevant section of the act: 6(1)
Offence: failure to appoint a construction engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
Reservoir AU
Undertaker: private individual
Undertaker Type: farms
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Reservoir AV
Undertaker: private individual
Undertaker Type: farms
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Reservoir AW
Undertaker: private individual
Undertaker Type: private individual
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Reservoir AX
Undertaker: private individual
Undertaker Type: private landowners and trusts
Relevant section of the act: 6(1)
Offence: failure to appoint a construction engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
Reservoir AY
Undertaker: private individual
Undertaker Type: private landowners and trusts
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
Reservoir AY
Undertaker: private individual
Undertaker Type: private landowners and trusts
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Reservoir AZ
Undertaker: private individual
Undertaker Type: private landowners and trusts
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: notice served
Compliance status on 31 December 2024: compliant
Reservoir B
Undertaker: private individual
Undertaker Type: farms
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
Reservoir BA
Undertaker: private individual
Undertaker Type: private landowners and trusts
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Reservoir BB
Undertaker: private individual
Undertaker Type: private individual
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
Reservoir BC
Undertaker: private individual
Undertaker Type: private landowners and trusts
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Reservoir BD
Undertaker: private individual
Undertaker Type: farms
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Reservoir C
Undertaker: private individual
Undertaker Type: private landowners and trusts
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Reservoir D
Undertaker: private individual
Undertaker Type: private landowners and trusts
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Reservoir E
Undertaker: private individual
Undertaker Type: private landowners and trusts
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Reservoir F
Undertaker: private individual
Undertaker Type: farms
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Reservoir G
Undertaker: private individual
Undertaker Type: farms
Relevant section of the act: 6(1)
Offence: failure to appoint a construction engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
Reservoir H
Undertaker: private individual
Undertaker Type: private landowners and trusts
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
Reservoir I
Undertaker: private individual
Undertaker Type: private landowners and trusts
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
Reservoir J
Undertaker: private individual
Undertaker Type: private landowners and trusts
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
Reservoir K
Undertaker: private individual
Undertaker Type: private individual
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: notice served
Compliance status on 31 December 2024: non-compliant
Reservoir K
Undertaker: private individual
Undertaker Type: private individual
Relevant section of the act: 10(7)(a)
Offence: failure to appoint an inspecting engineer
Enforcement action: notice served
Compliance status on 31 December 2024: non-compliant
Reservoir L
Undertaker: private individual
Undertaker Type: private landowners and trusts
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: notice served
Compliance status on 31 December 2024: compliant
Reservoir M
Undertaker: private individual
Undertaker Type: private landowners and trusts
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
Reservoir N
Undertaker: private individual
Undertaker Type: farms
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Reservoir O
Undertaker: private individual
Undertaker Type: private landowners and trusts
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
Reservoir P
Undertaker: private individual
Undertaker Type: private landowners and trusts
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
Reservoir Q
Undertaker: private individual
Undertaker Type: private landowners and trusts
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: notice served
Compliance status on 31 December 2024: compliant
Reservoir R
Undertaker: private individual
Undertaker Type: private landowners and trusts
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Reservoir S
Undertaker: private individual
Undertaker Type: private landowners and trusts
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: notice served
Compliance status on 31 December 2024: compliant
Reservoir T
Undertaker: private individual
Undertaker Type: farms
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Reservoir U
Undertaker: private individual
Undertaker Type: private landowners and trusts
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
Reservoir V
Undertaker: private individual
Undertaker Type: farms
Relevant section of the act: 6(1)
Offence: failure to appoint a construction engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
Reservoir W
Undertaker: private individual
Undertaker Type: farms
Relevant section of the act: 6(1)
Offence: failure to appoint a construction engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
Reservoir X
Undertaker: private individual
Undertaker Type: private individual
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
Reservoir X
Undertaker: private individual
Undertaker Type: local authority, private landowners and trusts
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Reservoir Y
Undertaker: private individual
Undertaker Type: farms
Relevant section of the act: 6(1)
Offence: failure to appoint a construction engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
Reservoir Z
Undertaker: private individual
Undertaker Type: farms
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
River Park Pond
Undertaker: Leconfield Estate
Undertaker Type: private landowners and trusts
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Rock Farm Old Lagoons
Undertaker: Coventry & Warwickshire Development Partnership LLP
Undertaker Type: private landowners and trusts
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: notice served
Compliance status on 31 December 2024: compliant
Rosehill Lake
Undertaker: Rosehill Carp Fishery
Undertaker Type: fish farms
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
Sandbeck Park (Upper Lake)
Undertaker: The Earl of Scarborough
Undertaker Type: private landowners and trusts
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Sandhurst Lower Lake
Undertaker: Ministry of Defence
Undertaker Type: other government agencies and departments
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: notice served
Compliance status on 31 December 2024: compliant
Sandhurst Upper Lake
Undertaker: Ministry of Defence
Undertaker Type: other government agencies and departments
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: notice served
Compliance status on 31 December 2024: compliant
Seeswood Pool
Undertaker: VISCOUNT DAVENTRY & Warwickshire County Council
Undertaker Type: private landowners and trusts
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Sefter Large Reservoir
Undertaker: Barfoot Farms Limited
Undertaker Type: farms
Relevant section of the act: 8(1)
Offence: failure to appoint a construction engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Shearwater Lake
Undertaker: Longleat Estates
Undertaker Type: private landowners and trusts
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
Shipley Lake
Undertaker: Derbyshire County Council
Undertaker Type: local authority
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
Shoulder of Mutton Pond
Undertaker: Bedford Estates Nominees Ltd
Undertaker Type: private landowners and trusts
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
Siblyback
Undertaker: South West Water Limited
Undertaker Type: water companies
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Smallburgh Reservoir
Undertaker: Worstead Farms Limited
Undertaker Type: farms
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Smiddyshaw
Undertaker: Northumbrian Water Limited
Undertaker Type: water companies
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
South Pickenham
Undertaker: The South Pickenham Estate Company Limited
Undertaker Type: farms
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Southrepps Hall Reservoir
Undertaker: WAYWARE LIMITED
Undertaker Type: farms
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
Spring Farm
Undertaker: Cooper Bros. (Wix) Ltd
Undertaker Type: farms
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Springslade Pool
Undertaker: KGL Estates Ltd
Undertaker Type: private landowners and trusts
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
Springslade Pool
Undertaker: KGL Estates Ltd
Undertaker Type: private landowners and trusts
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
Springwell Reservoir
Undertaker: Northumbrian Water Limited
Undertaker Type: water companies
Relevant section of the act: 2(2B)
Offence: failure to register a large raised reservoir
Enforcement action: warning letter
Compliance status on 31 December 2024: compliant
Stewartby Lake
Undertaker: Bedfordshire and River Ivel Internal Drainage Board
Undertaker Type: other government agencies and departments
Relevant section of the act: 10(7)(a)
Offence: failure to appoint an inspecting engineer
Enforcement action: notice served
Compliance status on 31 December 2024: compliant
Sticking Hill Reservoir
Undertaker: CH Cole & Sons
Undertaker Type: farms
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Stoke Park Lower Lake
Undertaker: Slough Borough Council
Undertaker Type: local authority
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Stoke Park Upper Lake
Undertaker: Stoke Park Limited
Undertaker Type: recreational clubs and associations
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Stowe Landscape Gardens, Octagon Lake
Undertaker: The National Trust
Undertaker Type: national trust
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
Sutton Place Lake
Undertaker: Sutton Place Property Unit Trust
Undertaker Type: private landowners and trusts
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: notice served
Compliance status on 31 December 2024: compliant
Sutton Place Lake
Undertaker: Sutton Place Property Unit Trust
Undertaker Type: private landowners and trusts
Relevant section of the act: 12(4) leading to a 17(1)(e) action
Offence: failure to appoint a supervising engineer
Enforcement action: notice served
Compliance status on 31 December 2024: compliant
Swanbourne Lake
Undertaker: Norfolk Estates
Undertaker Type: private landowners and trusts
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
Swanley Bridge Marina
Undertaker: Swanley Bridge Marina Limited
Undertaker Type: industrial and commercial
Relevant section of the act: 10(7)(a)
Offence: failure to appoint an inspecting engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Swanley Bridge Marina
Undertaker: Swanley Bridge Marina Limited
Undertaker Type: industrial and commercial
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Swanshurst Pool
Undertaker: Birmingham City Council
Undertaker Type: local authority
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Swiss Lake
Undertaker: The Trustees of the Chatsworth Settlement
Undertaker Type: private landowners and trusts
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
Sywell
Undertaker: North Northamptonshire Council
Undertaker Type: local authority
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Temple Lake
Undertaker: Sleekmade Property Company Ltd
Undertaker Type: industrial and commercial
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
The Large Lake, The Vyne
Undertaker: The National Trust
Undertaker Type: The National Trust
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
The Yeld Reservoir
Undertaker: EC Drummond (Agriculture) Limited
Undertaker Type: farms
Relevant section of the act: 6(1)
Offence: failure to appoint a construction engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Thoresby Lake (Upper)
Undertaker: Trustees of The Thoresby Settlement
Undertaker Type: private landowners and trusts
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Tidal Lake
Undertaker: Crystal Palace Park Trust
Undertaker Type: registered charities
Relevant section of the act: 10(7)(a)
Offence: failure to appoint an inspecting engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Tidal Lake
Undertaker: Crystal Palace Park Trust
Undertaker Type: registered charities
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Toddbrook
Undertaker: Canal & River Trust
Undertaker Type: Canal & River Trust
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
Torr Works Balancing Reservoir
Undertaker: Aggregate Industries Limited
Undertaker Type: industrial and commercial
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: notice served
Compliance status on 31 December 2024: compliant
Trotton Reservoir
Undertaker: Barfoot Farms Limited
Undertaker Type: farms
Relevant section of the act: 8(1)
Offence: failure to appoint a construction engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Tunstall
Undertaker: Northumbrian Water Limited
Undertaker Type: water companies
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Turners Paddock Lake
Undertaker: The National Trust
Undertaker Type: national trust
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Upper Cannop Pond
Undertaker: Forestry Commission
Undertaker Type: other government agencies and departments
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
Upper Compton Verney
Undertaker: Compton Verney House Trust
Undertaker Type: registered charities
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
Upper Compton Verney
Undertaker: Compton Verney House Charity | Mr and Mrs Cariss |
Undertaker Type: registered charities
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
Valentines Park Lake
Undertaker: London Borough of Redbridge
Undertaker Type: local authority
Relevant section of the act: 12(6)
Offence: failure to conduct visual inspection
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Walshaw Dean Lower
Undertaker: Yorkshire Water Services Ltd
Undertaker Type: water companies
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Walshaw Dean Middle
Undertaker: Yorkshire Water Services Ltd
Undertaker Type: water companies
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Ward’s (Blue Lagoon)
Undertaker: Blue Lagoon Heritage Ltd
Undertaker Type: industrial and commercial
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: notice served
Compliance status on 31 December 2024: compliant
Warnham Mill Pond
Undertaker: Horsham District Council, Environment Agency, Warnham Park Estate
Undertaker Type: local authority, Environment Agency, private landowners and trusts
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
Washpit Reservoir, Narford (Spitland Breck)
Undertaker: Trustees of the Fountaine Settlement
Undertaker Type: private landowners and trusts
Relevant section of the act: 6(1)
Offence: failure to appoint a construction engineer
Enforcement action: notice served
Compliance status on 31 December 2024: compliant
Waskerley
Undertaker: Northumbrian Water Limited
Undertaker Type: water companies
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
Waterden Reservoir
Undertaker: Holkham Farming Company Ltd
Undertaker Type: farms
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Watergate Park Lake
Undertaker: Gateshead Council
Undertaker Type: local authority
Relevant section of the act: 8(3)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Watergate Park Lake
Undertaker: Gateshead Council
Undertaker Type: local authority
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
Wentworth Park - Dog Kennel Pond
Undertaker: The Fitzwilliam Wentworth Amenity Trust
Undertaker Type: private landowners and trusts
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Wentworth Park - Mill Dam
Undertaker: The Fitzwilliam Wentworth Amenity Trust
Undertaker Type: private landowners and trusts
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Wentworth Park - Morley Pond
Undertaker: The Fitzwilliam Wentworth Amenity Trust
Undertaker Type: private landowners and trusts
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Weston-Super-Mare Strategic Flood Storage Superpond
Undertaker: North Somerset Council
Undertaker Type: local authority
Relevant section of the act: 8(3)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
Westwood
Undertaker: Sheffield City Council
Undertaker Type: local authority
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
Wharncliffe
Undertaker: The Warncliffe Estates
Undertaker Type: private landowners and trusts
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
White Water (Stamford)
Undertaker: Burghley House Preservation Trust Ltd
Undertaker Type: registered charities
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
Wimbledon Park Lake
Undertaker: London Borough of Merton
Undertaker Type: local authority
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: notice served
Compliance status on 31 December 2024: compliant
Wimbledon Park Lake
Undertaker: London Borough of Merton
Undertaker Type: local authority
Relevant section of the act: 10(7)(a)
Offence: failure to appoint an inspecting engineer
Enforcement action: notice served
Compliance status on 31 December 2024: compliant
Withins
Undertaker: Withins Reservoir Limited
Undertaker Type: private landowners and trusts
Relevant section of the act: 10(7)(b) leading to 17(1)(e) action
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: notice served
Compliance status on 31 December 2024: compliant
Withins
Undertaker: Withins Reservoir Limited
Undertaker Type: private landowners and trusts
Relevant section of the act: 10(7)(b) leading to 16(1) action
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: notice served
Compliance status on 31 December 2024: compliant
Withins
Undertaker: Withins Reservoir Limited
Undertaker Type: private landowners and trusts
Relevant section of the act: 10(7)(b) leading to 21(a) notice
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: notice served
Compliance status on 31 December 2024: compliant
Woburn Road Wetlands - Pond E (Bell Farm Pond E)
Undertaker: Bedford Borough Council
Undertaker Type: local authority
Relevant section of the act: 10(7)(a)
Offence: failure to appoint an inspecting engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Wollaton Park Lake
Undertaker: Nottingham City Council
Undertaker Type: local authority
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
Woodwalton Fen SSSI
Undertaker: Middle Level Commissioners
Undertaker Type: other government agencies and departments
Relevant section of the act: 8(3)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Woodwalton Fen SSSI
Undertaker: Middle Level Commissioners
Undertaker Type: other government agencies and departments
Relevant section of the act: 12A
Offence: failure to submit onsite flood plan certificates by deadline
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Worsbrough
Undertaker: Barnsley Metropolitan Borough Council
Undertaker Type: local authority
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
Wyldes Quarry (or Stevenshill) Reservoir ID209
Undertaker: Harnage Estates Ltd
Undertaker Type: private landowners and trusts
Relevant section of the act: 10(7)(a)
Offence: failure to appoint an inspecting engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
Wyldes Quarry (or Stevenshill) Reservoir ID209
Undertaker: Harnage Estates Ltd
Undertaker Type: private landowners and trusts
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: non-compliant
Wyndley Pool
Undertaker: Birmingham City Council
Undertaker Type: local authority
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Zen Reservoir (Courtauld Road)
Undertaker: Lime Property Fund (General Partner) Limited
Undertaker Type: private landowners and trusts
Relevant section of the act: 12(4)
Offence: failure to appoint a supervising engineer
Enforcement action: advice and guidance
Compliance status on 31 December 2024: compliant
Update on other third party non-compliant cases in England in appendix 1 of our 2021 to 2022 biennial report
Barcombe
Undertaker: South East Water Ltd
Undertaker Type: water companies
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice & guidance
Compliance status on 31 December 2024: non-compliant
Barden Lower
Undertaker: Yorkshire Water Services Ltd
Undertaker Type: water companies
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice & guidance
Compliance status on 31 December 2024: compliant
Barr Beacon 1
Undertaker: South Staffordshire Water PLC
Undertaker Type: water companies
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice & guidance
Compliance status on 31 December 2024: non-compliant
Berners Hall Farm
Undertaker: Essex Farms Ltd (K Daly)
Undertaker Type: farms
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice & guidance
Compliance status on 31 December 2024: non-compliant
Brine Reservoir, Wilton no. 4
Undertaker: Sabic UK Petrochemicals
Undertaker Type: industrial and commercial
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice & guidance
Compliance status on 31 December 2024: compliant
Digestate Reservoir No.1
Undertaker: Pretoria Energy Company (Mepal) Ltd
Undertaker Type: industrial and commercial
Relevant section of the act: 10(7)(a)
Offence: failure to appoint an inspecting engineer
Enforcement action: advice & guidance
Compliance status on 31 December 2024: compliant
Doe Hey Upper
Undertaker: Doe Hey Reservoir Company Limited
Undertaker Type: private landowners and trusts
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: notice served
Compliance status on 31 December 2024: non-compliant
Garden Lake (Stourhead)
Undertaker: The National Trust
Undertaker Type: The National Trust
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice & guidance
Compliance status on 31 December 2024: compliant
Hallington West
Undertaker: Northumbrian Water Ltd
Undertaker Type: water companies
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice & guidance
Compliance status on 31 December 2024: compliant
Heapey No. 1
Undertaker: Wigan & District Angling Association
Undertaker Type: recreational clubs and associations
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice & guidance
Compliance status on 31 December 2024: non-compliant
Heapey No. 2
Undertaker: Wigan & District Angling Association
Undertaker Type: recreational clubs and associations
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice & guidance
Compliance status on 31 December 2024: non-compliant
Heapey No. 3
Undertaker: Wigan & District Angling Association
Undertaker Type: recreational clubs and associations
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice & guidance
Compliance status on 31 December 2024: non-compliant
Hewell Grange
Undertaker: HM Prison Service
Undertaker Type: other government agencies and departments
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice & guidance
Compliance status on 31 December 2024: non-compliant
Leeds Castle Moat
Undertaker: Leeds Castle Foundation
Undertaker Type: private landowners and trusts
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice & guidance
Compliance status on 31 December 2024: non-compliant
Lower Cannop Pond
Undertaker: Forestry Commission
Undertaker Type: other government agencies and departments
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice & guidance
Compliance status on 31 December 2024: non-compliant
Mizzy Dam
Undertaker: The Earl of Derby’s Estate
Undertaker Type: private landowners and trusts
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice & guidance
Compliance status on 31 December 2024: non-compliant
Pembury
Undertaker: South East Water Ltd
Undertaker Type: water companies
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice & guidance
Compliance status on 31 December 2024: compliant
Sun Paper Mill
Undertaker: Blackburn Waterside Regeneration Ltd
Undertaker Type: private landowners and trusts
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: advice & guidance
Compliance status on 31 December 2024: non-compliant - works underway to discontinue the reservoir
Ward’s (Blue Lagoon)
Undertaker: Blue Lagoon Heritage Ltd
Undertaker Type: industrial and commercial
Relevant section of the act: 10(7)(b)
Offence: failure to complete safety measures by stipulated deadline(s)
Enforcement action: prosecution
Compliance status on 31 December 2024: compliant