Skip to main content
Guidance

Radon services for employers and workplaces

Information for employers about radon requirements in the workplace.

If your workplace could have high radon levels, follow this process to manage the risk:

Assess the risk of high radon levels.

Measure radon levels in higher-risk premises.

Act on any high results.

Maintain any radon reduction measures, review changes to the premises or how they are used, and assess whether retesting is needed.

Assess 

Employers must protect the health and safety of their employees and anyone else who may be affected by their work, so far as is reasonably practicable. 

Under the Health and Safety at Work Act 1974 and Management of Health and Safety at Work Regulations 1999, employers must assess health and safety risks and take action to remove or control them. This includes carrying out a risk sufficient assessment and taking suitable actions.

As radon comes from the ground, underground areas are more likely to have high levels. UKHSA advises employers to identify radon as a workplace hazard if any of the following apply: 

  • the workplace is in a radon Affected Area 

  • there is a basement occupied for more than about 50 hours each year 

  • workplace is wholly underground; such as mines, tunnels and caves 

  • there may be internal sources of radon, such as geological samples or ground water

Employers should seek specialist advice from us for wholly underground workplaces and workplaces where there may be an internal source of radon. 

The level radon in a building depends on its location, construction, amount of ventilation and how the building is used. Although work environments vary greatly, elevated radon levels can occur in almost any type of workplace. 

Radon levels can vary significantly within the same building. An individual’s exposure depends on the radon levels in the areas where they spend most of their working time. 

It is important to measure radon in locations that represent where employees spend most of their time within the building so that the assessment accurately reflects staff exposure. Read more about health risks of radon.

Measure 

Testing is generally undertaken in ground floor rooms that are used routinely. Other rooms, on higher floors or those in which people spend little time, do not generally need to be tested.  If your company occupies a shared building and not on the ground floor – you should test your lowest occupied level in the building which may be an upper storey. 

If radon is an identified hazard, the workplace should be tested. Regulations apply if the radon level exceeds 300 Bq m⁻³ as an annual average in any area. The combination of the radon level, occupancy time and workplace type will determine what action is required.

Number of detectors to order 

If you have many premises to test, consider how you are going to manage the logistics.

Workplace type Number of monitors Examples
Office, individual or small One per 100 m², generally corresponds to between a half and third of all ground floor rooms Banks, small shops, professional practice (solicitors, etc), residential homes, schools
Open plan office, and retail or workshop up to about 1000 m², also public access areas One per 250 m² Administrative and call centres, light industry, hotels
As above, up to 5000 m² One per 500 m² Large retail etc
Very large areas of several thousand m² One for each distinct area with obviously different environmental conditions, not less than 1 per 1000 m² Manufacturing or process plant, warehouses
Basements Should be monitored if occupied for more than 50 hours per year (~ an hour per week). One monitor for each occupied room, section or area. Basements with generally high occupancy should be monitored using the rules as for ground floors Retail, bank and professional storage areas
Wholly underground As a guide at least one in each main working area, and other normally occupied areas, but seek specialist advice Water industry, mines and caves

Effect of ventilation - In principle, radon may be prevented from accumulating in premises with particularly high influx of fresh air, but a measurement is still required unless a risk assessment can show that the radon level at a particular location is necessarily low at all times when it is occupied. Furthermore, there will often be adjoining or linked places, such as an office, store, computer area or access duct, with quite different conditions where a measurement would be required.

Downloadable version: Workplace radon detectors monitors - guidance table (PDF, 69.2 KB, 2 pages)

Act 

If the annual average radon level in any part of a workplace exceeds 300 becquerels per cubic metre (Bq m⁻³), The Ionising Radiations Regulations 2017 (or The Ionising Radiations Regulations (Northern Ireland) 2017) apply. 

In these circumstances, the employer must take action to protect staff and comply with legal requirements. Your UKHSA radon gas test report will include practical advice on the steps you could take to manage and reduce radon levels and meet regulatory requirements. 

If radon levels are below the workplace threshold, employers should keep a record of the results and review them after around 10 years, or sooner if there are significant changes to the building’s structure or how the workplace is used.

Further guidance is available from the Health and Safety Executive (HSE).

Maintain 

Radon levels can vary over time. This is usually because of changes to the construction of the building or alterations to heating and ventilation which can be caused by a change in use. For this reason: 

  • radon should remain in your routine reviews of risk assessments 

  • consider any changes and assess whether the test needs to be repeated 

  • check radon levels annually, even if a radon reduction system is installed, as these systems can become less effective over time and may need maintenance or updates before they fail

Information to pass to employees 

If measurements show radon levels above the action threshold, you should provide employees with information about the results, the potential for exposure, and the steps being taken to reduce the risk.

You can use the following text:


Potential for exposure to radon gas at work

Radon gas measurements have been carried out in our premises, which are located in areas where there is a greater chance of high levels. These measurements were arranged as part of this organisation’s obligations under the Management of Health and Safety at Work Regulations 1999.

The results of the measurements show that at least one of the results exceeds the action threshold of 300 Bq m⁻³ annual average. Therefore the Ionising Radiations Regulations 2017 (or the Ionising Radiations Regulations (Northern Ireland) 2017 where applicable) apply to work in the premises.

Consequently, we are required to implement various administrative and practical steps to restrict exposure to radon gas. This includes providing information to employees about the potential for radiation exposure during work, which is the purpose of this note.

What this means for you

The risk to health is a combination of the radon level and the time spent at that exposure.

Employers are required to do a risk assessment and limit the overall risk to as low as possible so as not to exceed the regulations and, where possible, to be below the public radiation dose limit.

This is done by either:

  • reducing the level, or
  • limiting the use of high areas

Health risks

Short-term exposure will not significantly add to your risk, so there is no need for undue concern.

The health risk from radon is from continued long-term exposure to high levels.

Once one of the 2 steps above has been taken to reduce the exposure of staff, the regulations will cease to apply.


Further information 

IRR17 information

Request an accessible format
If you use assistive technology (such as a screen reader) and need a version of this document in a more accessible format, please email publications@ukhsa.gov.uk. Please tell us what format you need. It will help us if you say what assistive technology you use.

Radon in schools (IRR17)

Request an accessible format
If you use assistive technology (such as a screen reader) and need a version of this document in a more accessible format, please email publications@ukhsa.gov.uk. Please tell us what format you need. It will help us if you say what assistive technology you use.

Sign up for emails or print this page