Monitoring stack gas emissions: use of standby and surrogate monitoring at waste incinerators and co-incinerators

Updated 13 November 2026

Applies to England

This guidance is for operators of waste incinerators and co-incinerators. It explains what you must do if either of the following fail:

  • your continuous emissions monitoring systems (CEMS) that measure particulate matter, carbon monoxide or total organic carbon
  • a peripheral measurement needed to express results at the same reference conditions as the emission limit values (ELVs)

Alternative monitoring during periods of abnormal operation

Abnormal operation is defined in your permit. It includes periods of time when CEMS are unavailable.

During abnormal operation, you must not exceed the ELVs for periods of abnormal operation for emissions of:

  • particulate matter
  • carbon monoxide
  • total organic carbon

You may use standby CEMS for these pollutants, or a surrogate measurement as a substitute for carbon monoxide or total organic carbon. A surrogate is a measurement of one pollutant used as a substitute for the measurement of another pollutant.

You must still take peripheral measurements of the following to correct results to the same reference conditions that the ELV is expressed at:

  • oxygen
  • water vapour
  • stack temperature and pressure

You may use a substitute for these if they fail.

There is information on substituting missing peripheral measurements in EN 17255-1 Stationary source emissions – Data acquisition and handling systems – Part 1: Specification of requirements for the handling and reporting of data.

Use of standby CEMS when the main CEMS fail

If your main CEMS fail, you may use back-up standby CEMS, which monitor the same stacks as the main CEMS. The standby CEMS must be MCERTS certified for the measurands and ranges that apply. They must also be calibrated for the process they are monitoring, further information on calibration of standby CEMS is available in Monitoring stack gas emissions: quality assurance of continuous monitoring.

Using a surrogate when CEMS fail

If CEMS fail, you may use:

  • carbon monoxide as a surrogate for total organic carbon
  • total organic carbon as a surrogate for carbon monoxide

If you wish to do this, you must demonstrate there is a sufficiently strong correlation between the surrogate and the pollutant it is a surrogate for. You must submit this to the Environment Agency for approval.

Surrogates do not need to comply with the uncertainty budget applied to CEMS.

If you have feedback

If you have any comments on this document or any questions about MCERTS, please contact the National Customer Contact Centre.

General enquiries

National Customer Contact Centre
PO Box 544
Rotherham
S60 1BY

Email enquiries@environment-agency.gov.uk

Telephone 03708 506 506

Telephone from outside the UK (Monday to Friday, 8am to 6pm GMT) +44 (0) 114 282 5312

Monday to Friday, 8am to 6pm.