Portable air-conditioning in education settings
Published 17 November 2026
Applies to England
During hot weather, portable air-conditioning units can be used in specific spaces as a short-term measure, including to support the delivery of exams.
Practical considerations for using portable air conditioning
The suitability of portable air-conditioning units will depend on the characteristics of individual buildings and the spaces in which they are intended to be used. For example, examinations are often held in sports halls or other large spaces, so careful consideration is needed to ensure that they can be vented to the outside.
Portable air-conditioning units are typically noisier than fixed air-conditioning systems. During periods of extreme heat, this additional noise may be considered an acceptable trade-off for the cooling provided. Where units are being used to support examination spaces, settings can operate them before and between examinations to reduce the potential impact of noise during exams.
Consider how portable units will work in your space, including:
- whether suitable power outlets are available at the intended location
- how units will connect to the outside for venting
- any security implications associated with windows, doors or other openings used to vent hot air
- whether ducting, hoses or power cables could create trip hazards, particularly in circulation routes
- how units will be stored safely and securely when not in use
- the noise of units in operation and potential impacts on occupants
Minimum recommended performance for a portable air conditioning unit
The following considerations should be taken into account when selecting portable air conditioning units:
- the cooling capacity: ensure the unit is appropriately sized for the room – larger exam halls or spaces with high occupancy may require multiple units
- condensate management: including how water will be removed
- energy efficient performance
- ease of maintenance: including accessibility for cleaning or replacing filters
- controls and functionality: including programmable timers, temperature settings, alarms and filter-change indicators
- product compliance and certification: including UKCA or CE marking and a Declaration of Conformity
- manufacturer’s operating and maintenance instructions: including any requirements relating to installation, ventilation, servicing and safe operation