Product Safety Report: LED Ceiling Light, JM6001 (2610-0098)
Product Safety Report for LED Ceiling Light, JM6001 presenting a serious risk of fire.
Summary
Product: LED Ceiling Light, JM6001
Hazard: The product presents a serious risk of fire because it is fitted with an incorrect supply cord which has excessive electrical resistance and could overheat during use, causing the insulation to melt or ignite nearby combustible materials.
Corrective action: The import has been rejected at the border
Product information
| Type | Lighting equipment – Mounted Lighting |
|---|---|
| Model | JM6001 |
| Country of Origin | China |
| Product Description | A LED ceiling light with wiring for installation. |
| Product Report and Image |
Hazard
The product presents a serious risk of fire because it is fitted with an incorrect supply cord which has excessive electrical resistance and could overheat during use, causing the insulation to melt or ignite nearby combustible materials. The product also has inadequately insulated mains wiring in contact with unearthed metallic parts and failed the electric strength test required for Class II equipment. The product was also missing required markings, instructions and safety instructions.
The product does not meet the requirements of the Electrical Equipment (Safety) Regulations 2016.
Corrective action
The import has been rejected at the border.