Product Recall: Hilti (GB) Limited Ventilated Cavity Barriers (CFS-VB) - E60 50 (Sizes 150-350mm) and E120 25 (sizes 175-375mm) (2602-0235)
Product Recall for specific product codes and ranges of Hilti (GB) Limited Ventilated Cavity Barriers found not to consistently achieve the declared reaction to fire performance.
Summary
Product: Hilti (GB) Limited Ventilated Cavity Barriers (CFS-VB) - E60 50 (Sizes 150-350mm) and E120 25 (sizes 175-375mm)
Hazard: The product has been found not to consistently achieve the declared reaction to fire performance.
Corrective action: Hilti (GB) Limited have issued a recall for a limited number of specific product codes and ranges of ventilated cavity barriers.
Product information
| Type | Construction Products – Ventilated Cavity Barrier |
|---|---|
| Model | (CFS-VB) - E60 50 (Sizes 150-350mm) and E120 25 (sizes 175-375mm) |
| Product Codes | 2395739 2395750 2395751 2395754 2395755 2395756 2395757 2395759 2395760 2395761 2395762 2395763 2395764 2395165 2395766 |
| Country of Origin | Slovenia |
| Product Description | Ventilated cavity barrier comprised of a mineral wool slab, intumescent strip(s) and GF reinforced PE foil. |
| Product Report and Image |
Hazard
Hilti (GB) Limited have identified that, due to a manufacturing fault, the active component of the CFS-VB ventilated cavity barrier might not be properly attached. The staples used to fix the intumescent strip in place to the mineral wool component of the cavity barrier may not be of the required number. This may lead to partial detachment of the intumescent strip in the case of fire, potentially reducing the final fire performance of the cavity barrier.
Corrective action
Hilti (GB) Limited have issued a recall for a limited number of specific product codes and ranges of ventilated cavity barriers. Affected projects have been notified of the issue directly.
Hilti (GB) Limited’s team can be contacted on 0800 886 100 or gbhiltiproductquality@hilti.com for project managers with questions or requiring assistance.
Additional information
PSD notification number: 2602-0235
Notified by: Office for Product Safety and Standards