Fire on board ro-ro passenger ferry Dieppe Seaways resulting in 3 people injured

Location: Approach to Eastern Ferry Terminal, Port of Dover

Accident Investigation Report 20/2015

Investigation report into marine accident including what happened, safety lessons and recommendations made:

MAIB investigation report 20-2015: Dieppe Seaways

Annexes to MAIB investigation report 20-2015

Photograph of ferry Dieppe Seaways

Photograph courtesy of FotoFlite.com

Summary

On 1 May 2014, the DFDS A/S ferry Dieppe Seaways was approaching the Eastern Ferry Terminal at the Port of Dover when an uncontrolled fire broke out in the furnace of the port thermal oil heater.

The investigation has identified that a crack in the thermal oil heater coil allowed thermal oil to enter the furnace, resulting in an uncontrolled furnace fire. It is concluded that the coil failed as a result of stress caused by the weld securing the refractory insulation support plate.

Safety issues

  • Importance of positive control of firefighting efforts with ship’s master retaining overall responsibility for the safety of the ship and crew.
  • The overarching requirement for the command team to continually review actions taken by both ship’s crew and shore firefighters ensuring that their actions are complementary and do not compromise each other’s safety.
  • Maintenance records must be comprehensive highlighting equipment failures/deficiencies to allow inspections and surveys to focus on high risk areas.

Recommendations

Recommendations have been made to the thermal oil heater manufacturer, Prozess-Wärmeträgertechnik GmbH (2015/148), to investigate alternative methods of securing the refractory insulation plate; the ship’s classification society, Det Norske Veritas Germanischer Lloyd (2015/149), to provide additional guidance to its surveyors with regard to examining thermal oil heaters; Kent Fire and Rescue Service (2015/150) in respect of shipboard training and procedures; and both Det Norske Veritas Germanischer Lloyd and DFDS A/S (2015/151), to review the suitability of dry powder as a fixed fire-extinguishing medium for use in thermal oil heater furnaces.

Published 7 October 2015