Air pollution monitoring: Polycyclic Aromatic Hydrocarbon Network
The Polycyclic Aromatic Hydrocarbon (PAH) Network monitors polycyclic aromatic hydrocarbons (PAHs).
PAH Network data is available from:
- 36 monitoring stations that measure PAHs in air
- 2 monitoring stations that measure PAHs in deposition (deposition is when pollutants in the air settle on land, water or vegetation)
PAHs are toxic and long-lasting (persistent) organic pollutants. They are usually created through incomplete combustion or pyrolysis (when organic material is decomposed by heat without oxygen).
PAHs are carcinogenic, which means they can cause cancer in humans (check the health effects of PAHs).
Purpose of the PAH Network
The purpose of this network is to:
- monitor levels of PAHs in the air and track how they change over time at typical industrial, urban and rural locations across the UK
- check compliance with the Air Quality Standards Regulations 2010
Get air pollution data
Get air pollution data from the PAH Network. Verified data is published every 6 months.
You can get PAH Network data from:
- deposition analysers at Auchencorth Moss (2009 to present), Chilbolton Observatory (2016 to present) and Harwell (2008 to 2016)
- Andersen analysers (1991 to 2007)
- Digitel analysers - solid phase particulate (PM10) data from PAH Digitel DHA-80 analysers (2007 to 2016)
- Digitel analysers - solid phase and vapour particulate (PM10) data from PAH Digitel DHA-80 analysers (2007 to present)
The National Atmospheric Emissions Inventory (NAEI) estimates emissions of PAHs in the UK.
Pollutants this network measures
This network measures:
- PAHs in PM10 (particulate matter less than 10 micrometres in diameter)
- PAHs in deposition
PAHs in PM10
This network measures the following PAHs in PM10:
- 5-methyl chrysene
- anthanthrene
- benzo[a]anthracene
- benzo[a]pyrene
- benzo[b]fluoranthene
- benzo[j]fluoranthene
- benzo[b]naptho[2,1-d]thiophene
- benzo[c]phenanthrene
- benzo[e]pyrene
- benzo[ghi]perylene
- benzo[k]fluoranthene
- cholanthrene
- chrysene
- coronene
- cyclopenta[cd]pyrene
- dibenzo[a,c]anthracene
- dibenzo[ae]pyrene
- dibenzo[ah]anthracene
- dibenzo[ah]pyrene
- dibenzo[ai]pyrene
- dibenzo[al]pyrene
- indeno[123-cd]pyrene
- perylene
PAHs in deposition
This network measures the following PAHs in deposition:
- 1-methyl naphthalene
- 1-methylanthracene
- 1-methylphenanthrene
- 2-methylanthracene
- 2-methylnaphthalene
- 2-methylphenanthrene
- 4H-cyclopenta[def]phenanthrene
- 5-methyl chrysene
- 9-methylanthracene
- acenaphthene
- acenaphthylene
- anthanthrene
- anthracene
- benzo[a]anthracene
- benzo[a]pyrene
- benzo[b]fluoranthene
- benzo[b]naptho[2,1-d]thiophene
- benzo[c]phenanthrene
- benzo[e]pyrene
- benzo[ghi]perylene
- benzo[j]fluoranthene
- benzo[k]fluoranthene
- biphenyl
- cholanthrene
- chrysene
- coronene
- cyclopenta[cd]pyrene
- dibenzo[ae]pyrene
- dibenzo[ah]pyrene
- dibenzo[ai]pyrene
- dibenzo[al]pyrene dibenzo[a,c]anthracene
- dibenzo[ah]anthracene
- fluoranthene
- fluorene, indeno[123-cd]pyrene
- naphthalene
- perylene
- phenanthrene
- pyrene
- retene
Monitoring instruments and methods
This network uses a manual (non-automatic) sampling method. PAHs deposition and particle samples are collected on filters and analysed in a laboratory.
Monitoring solid-phase PAHs
PAHs trapped on solid particles (like dust or soil) is measured using solid-phase extraction techniques. Solid phase filter samples are measured every 24 hours at a flow rate of approximately 30m3 per hour.
Samples of PAHs in PM10 are taken each day at all monitoring stations using Digitel DHA-80 samplers with automatic filter changers.
The samples are combined into calendar month groups for analysis using gas chromatography–mass spectrometry.
Monitoring PAHs in deposition
Samples of PAHs in deposition are collected every 2 weeks from the monitoring stations at:
- Auchencorth Moss in Midlothian, Scotland
- Chilbolton Observatory in Hampshire, England
The sampler is a glass funnel and a 4-litre glass collection bottle. It’s in a protective tube to minimise PAHs degradation and photochemical reactions with sunlight.
The samples are collected and analysed using gas chromatography–mass spectrometry.
The samplers meet the requirements of the European Standard for measuring deposition of PAHs (EN 15980:2011).
Historic measurements
Between 1991 and 2007 this network used Andersen GPS-1 pesticide samplers with omi-directional heads to sample PAHs in ambient air.
In 2008 the network sampler changed to a Digitel DHA-80 high volume PM10 aerosol sampler with a 1-day sampling period.
PAH Network annual reports
View PAH Network annual reports.
Network start date
This network started in 1991.