Skip to main content
Guidance

Air pollution monitoring: National Ammonia Monitoring Network

The National Ammonia Monitoring Network (NAMN) monitors air pollution from gaseous ammonia (NH3) and particulate ammonium (NH4+). 

The NAMN is part of the UK Eutrophying and Acidifying Atmospheric Pollutants (UKEAP) Network. UKEAP networks monitor how air pollution levels change over time, mainly in remote and rural areas.

Ammonia damages sensitive ecosystems by: 

  • adding excess nutrients, through eutrophication
  • making soils and water more acidic, through acidification

Find out how ammonia can impact human health. 

Get air pollution data 

Get air pollution data from the NAMN. 

Samples from this network are collected every month and analysed in a laboratory. The data is published every 3 months.

Purpose of this network 

The main objectives of this network are to: 

  • track changes in levels of ammonia and ammonium over time 
  • understand how ammonia gas converts into particles in the air 

This network: 

  • monitors levels of ammonia and ammonium in the air, and the amount that settles onto land and water 
  • helps us understand how changes in agriculture can affect ammonia and ammonium levels 

Monitoring instruments and methods 

There are 111 monitoring stations in the NAMN. The stations collect data using the following instruments:  

  • active DELTA (DEnuder for Long-Term Atmospheric) samplers (at 28 stations) 
  • passive ALPHA (Adapted Low-cost Passive High Absorption) samplers (at 93 stations) 

Both these instruments were developed by the UK Centre for Ecology and Hydrology (UKCEH). 

Active DELTA samplers pull air through filters and collectors which capture pollutants including ammonia and ammonium.  

Passive ALPHA samplers collect ammonia without pumps or electricity.  

There are 9 sites that use both samplers. This is to correct ALPHA measurements against DELTA measurements. This happens once a year. 

The samplers use a calibration value called the uptake rate. This determines how much air the sampler collects over time. It follows the requirements of the European standard EN 17346:2020 for measuring ammonia using diffusive samplers. 

The uptake rate is determined by comparing the results from ALPHA samplers with the DELTA samplers. The DELTA samplers are used as the reference method. 

Using these comparisons, a new uptake rate is calculated each year. The value is then reviewed and applied across the network to ensure that ammonia measurements from the ALPHA samplers remain accurate and consistent. 