Airborne per- and polyfluoroalkyl substances (PFAS): emissions and monitoring: summary
Published 12 November 2026
Applies to England
1. Chief Scientist’s Group report summary
This project examined how per- and polyfluoroalkyl substances (PFAS) may be released to air from industrial and waste-management activities regulated by the Environment Agency. It also reviewed available and emerging methods for monitoring PFAS in ambient air. Scientific and technical literature, regulatory information and expert evidence were used to identify potential emission sources, release pathways, monitoring techniques and important evidence gaps. The findings provide an evidence base to support future monitoring, regulation and risk-management decisions.
Our evidence review indicates that PFAS can be measured in air and a number of analytical methods are available to achieve this. However, key limitations relate to the range of PFAS captured by individual methods which are currently very limited, how representative measurements are of emissions and exposure, and whether data generated using different methods are sufficiently consistent and comparable to support regulatory decision-making.
1.1 Background
The Environment Agency regulates major industrial and waste-management facilities in England. PFAS are a large group of persistent synthetic chemicals used in many industrial processes and consumer products. Some PFAS released from industrial processes can travel through the atmosphere and may contribute to wider environmental contamination and human exposure.
Although monitoring of PFAS in water is well established, air monitoring remains limited. There is currently no standard approach for measuring concentrations of the chemicals in ambient air. Better information about where airborne PFAS emissions arise, which substances are released, their physical form and their resulting concentrations is needed. This would help to assess their potential significance and determine whether further monitoring or regulatory action is needed.
1.2 Approach
A structured review of scientific literature, regulatory information and other publicly available evidence was conducted. This covered airborne PFAS emissions from relevant industrial and waste-management activities, including chemical manufacturing, metal processing, energy production and waste management.
Established and emerging sampling and analytical methods for PFAS in ambient air were reviewed, considering their strengths, limitations, costs, sensitivity and operational requirements. The feasibility of incorporating PFAS measurements into existing UK air-monitoring networks was also evaluated.
1.3 Results
A wide range of regulated activities have the potential to emit PFAS to air. The strongest evidence was found for fluoropolymer manufacturing, fluorocarbon production, semiconductor manufacture, metal plating, landfill and waste incineration. Emission sources include stacks, vents and treatment systems; fugitive releases may occur from equipment, storage and industrial processes.
The PFAS compounds emitted vary between sectors and according to their physicochemical properties. Volatile PFAS may be released directly to air, while less volatile substances may be carried in aerosols, dusts or smoke. Atmospheric transformation of PFAS precursors may also occur, which further contributes to atmospheric PFAS concentrations and their wider distribution. Quantitative emission data are often scarce, inconsistent or difficult to compare, so it was not possible to rank industrial sectors by their overall potential emissions.
No internationally agreed standard method currently exists for monitoring PFAS in ambient air. Two main sampling approaches are available:
- Active sampling: in which air is drawn through specialised equipment and collection media.
- Passive sampling: in which pollutants accumulate naturally on exposed devices over time.
Active methods generally provide greater sensitivity and shorter sampling periods but require power, specialist equipment and higher operating costs. Passive methods are cheaper and easier to deploy widely, although they need longer sampling periods and may have higher detection limits. Analytical methods are available for some well-studied PFAS, while newer approaches are being developed for more novel substances.
Monitoring a range of individual PFAS through the UK Toxic Organic Micro Pollutants network appears technically feasible. Existing infrastructure, power supplies and trained personnel could potentially be used, although additional sampling, laboratory analysis and quality-control requirements would increase costs.
1.4 Conclusions
Many regulated activities may emit PFAS to air, but the quantities released remain poorly characterised. Established and emerging monitoring techniques are available, and both active and passive sampling could be used depending on the monitoring objectives. With suitable adaptations, monitoring for some PFAS could potentially be incorporated into existing UK infrastructure.
The study findings identify emission sources, monitoring options and evidence gaps. They will help the Environment Agency and other organisations improve understanding of airborne PFAS, evaluate environmental risks and consider future monitoring and regulatory approaches.
1.5 Publication details
This summary combines findings from project SC250006 reported in detail in the following outputs:
- SC250006/R1: Characteristics of airborne per- and polyfluoroalkyl substances (PFAS) emissions from regulated sites
- SC250006/R2: Methods for monitoring and evaluating airborne per- and polyfluoroalkyl substances (PFAS)
- Science manager: Philippa Douglas, Chief Scientist’s Group
- Research contractor: Air Quality Consultants Ltd
Enquiries: research@environment-agency.gov.uk.
© Environment Agency