Research and analysis

Table 5: descriptions of large-scale system tests undertaken by the BRE and the number of buildings with similar cladding systems

Updated 6 December 2018
Download CSV 1.12 KB

Large-scale system test ACM cladding category tested Insulation type tested Result Private Buildings Local authority Housing association Publicly-Owned Buildings Total Buildings
1 Category 3 Foam Insulation Fail 46 9 30 2 87
2 Category 3 Mineral Wool Fail 22 33 49 0 104
3 Category 2 PIR foam Fail 4 1 3 0 8
4 Category 2 Mineral Wool Pass 5 1 5 1 12
5 Category 1 Foam Insulation Pass 0 0 0 0 0
6 Category 1 Mineral Wool Pass 0 0 0 0 0
7 Category 2 Phenolic Foam Fail 9 0 14 0 23
Na Category 3 Not in a systems test Inferred fail 54 2 12 5 73
Na Category 2 Not in a systems test Inferred fail 18 0 0 2 20
Na Category 1 Not in a systems test Inferred pass 0 0 0 0 0
Subtotal: Total number of buildings failed BRE test Not set Not set Not set 153 45 108 9 315
Confirmed by local authorities as having similar ACM cladding systems to those which have failed large-scale system tests Not set Not set Not set 119 1 6 0 126
Total number of buildings with unsafe ACM cladding which are unlikely to meet current building regulation Not set Not set Not set 272 46 114 9 441
Subtotal: Total number of buildings passed BRE test Not set Not set Not set 5 1 5 1 12
Total number of buildings with confirmed ACM Not set Not set Not set 277 47 119 10 453