AAIB investigation to Freefly Systems Inc. Alta X (UAS, registration n/a)

Low battery voltage resulting in loss of control, Henley-on-Thames, Oxfordshire, 29 June 2022.

Summary:

The UAS, an Alta X, was being operated commercially to provide video footage at the Henley Royal Regatta when a low voltage battery warning occurred in flight at a height of 50 m. As the aircraft was being flown back to the landing site, the aircraft battery voltage reduced to the point where controlled flight was lost. It fell, in near free fall, and impacted a boat on the river, causing damage. No persons were injured. The pilot could not recall checking the aircraft’s battery voltage prior to takeoff, and the low voltage battery warning had been changed to trigger at a lower level than that recommended by the manufacturer.

Bulletin correction

A correction was issued concerning this report prior to publication and the online version of the report amended. Details of the correction can be viewed below:

Correction: Freefly Systems Inc. Alta X (UAS registration n/a) 02-23

Download report:

Freefly Systems Inc. Alta X, 01-23

Download glossary of abbreviations:

Glossary of abbreviations

Published 12 January 2023